    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems

    VKL11 RCCB Residual Current Circuit Breaker break time under I△n 10ms~300ms type G short-time delay

    VKL11 Residual Current Circuit Breaker RCCB TYPE G short-time delay


    1. General

    1.1 Function

    Residual Current Circuit Breaker VKL11F TYPE F EV (RCCB TYPE F EV) is the Type EV RCCB which has been developed specifically for EV charging systems and can detect AC and DC residual currents in accordance with the requirements of EN61008-1 and EN62423(function for detecting smooth DC residual current and a tripping threshold of 6mA )

    The VKL11F RCCB TYPE F EV also detects residual currents with mixed frequencies which is different from 50Hz. Electronic wiring and power electronics are required in electric vehicles for charging purposes. In the event of a fault, these can give rise to smooth DC residual currents and residual currents with mixed frequencies.The VKL11F RCCB TYPE F EV is also short-time delayed and has increased surge current strength. This significantly reduces the risk of faulty tripping.

    1.2 Selection

    Detectable wave form

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC

    residual currents

    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

    Smooth DC 6mA

    smooth DC residual currents (switch-off at max 6 mA)


    1.3 Approvals and certificates :UKCA,CE


    Tripping sensitivity

    30mA - 50Hz sinusoidal AC ; Pulsating DC

    Smooth DC ≥ 6 mA (RDC-PD)

    Tripping time

    short time delayed (G )


    2. Outline and installation dimensions (mm)



    3. Technical parameters

    StandardIEC/EN 61008-1 & EN62423
    Electrical featuresModel No.VKL11
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n30mA
    DC tripping threshold6mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui500V
    Rated frequency50/60 Hz

    Rated residual making and

    breaking capacity I△m

    500A (In=16A, 25A, 32A, 40A)
    630A(In=63A), 800A(In=80A), 1000A(In=100A)
    Short-circuit current Inc=I△c6000A, 10000A,1500 A

    Rated making and breaking capacity Im

    Peak withstand current

    3 kA (8/20 μs) surge current proof
    Type (wave form of the earth leakage sensed)

    AC, A

    Smooth DC 6mA

    Tripping timeShort time delayed
    break time under I△n

    10ms~300ms

    (G,type)

    Rated impulse withstand voltage(1.2/50) Uimp6kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 55℃
    Storage temperature-40℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom
    StandardEN61008-1 ,EN62423,OVE E8601

    Product Description:

    Residual Current Circuit Breaker Inmetro (RCCB) is a device designed to protect people from electric shock and fire caused by short circuits and leakage currents. It is certified by CE, ISI, NF, SEMKO, VDE and KEMA and has a rated residual operating current ranging from 30mA to 300mA, a rated current ranging from 16A to 100A, and a rated voltage of 230V AC. In addition, its rated operating duration is no more than 1s. RCCB is highly reliable and can effectively protect people from electric shock and fire.

    Features:

    • Product Name: Residual Current Circuit Breaker RCCB
    • Type: Residual Current Circuit Breaker type F EV
    • Mark: Residual Current Circuit Breaker with ISI mark
    • Rated Voltage: 240/415V AC
    • Rated Insulation Voltage: 500V
    • Rated Impulse Withstand Voltage: 4kV
    • Rated Residual Operating Current: 30mA-300mA
    • Rated Service Impulse Withstand Voltage: 6kV

    Applications:

    HAROK VKL11 Residual Current Circuit Breaker RCCB is a reliable safety device used to protect people and properties from electrical shock, electrical fire and other hazardous conditions. It is certified by Inmetro, NF SEMKO VDE KEMA, ensuring that it meets the highest safety standards. It is designed with high-performance features and is convenient to install, making it the perfect choice for residential, commercial and industrial applications.

    HAROK VKL11 RCCB is rated for a frequency of 50/60Hz, a short-circuit breaking capacity of 10kA and a rated voltage of 240/415V AC. In addition, it has a rated ultimate short-circuit breaking capacity of 10kA, providing an exceptionally reliable safety device. It is also easy to maintain and has a long service life.

    HAROK VKL11 RCCB is available in a minimum order quantity of 5000 units. It is delivered in a paper carton and can be shipped within 4-6 weeks after payment. It is available with a CE, ISI, NF, SEMKO, VDE and KEMA certificate and can be purchased on FOB NINGBO or SHANGHAI terms with a maximum supply capacity of 100,000 PCS PER MONTH.

    Technical Parameters:

    ParameterValue
    Rated Short-Circuit Breaking Capacity10kA
    Rated Frequency50/60Hz
    Rated Insulation Voltage500V
    Rated Ultimate Short-Circuit Breaking Capacity10kA
    Rated Residual Operating Current30mA-300mA
    Rated Voltage240/415V AC
    Rated Residual Current Off-Time≤0.1s
    Rated Service Impulse Withstand Voltage6kV
    Rated Impulse Withstand Voltage4kV

    Customization:

    Residual Current Circuit Breaker RCCB

    Brand Name: HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Certification: NF, SEMKO, VDE, KEMA, ISI, CE

    Minimum Order Quantity: 5000

    Packaging Details: PAPER CARTON

    Delivery Time: 4-6 weeks after payment

    Payment Terms: FOB NINGBO or SHANGHAI

    Supply Ability: 100,000 PCS PER MONTH

    Residual Current Circuit Breaker Inmetro, Residual Current Circuit Breaker NF SEMKO VDE KEMA , Residual Current Circuit Breaker Inmetro ISI CE

    Rated Service Impulse Withstand Voltage: 6kV

    Rated Operating Frequency: 50/60Hz

    Rated Current: 16A-100A

    Rated Residual Operating Current: 30mA-300mA

    Rated Frequency: 50/60Hz

    Packing and Shipping:

    Packaging and Shipping

    Residual Current Circuit Breaker (RCCB) products should be properly packaged and shipped in order to ensure their safe delivery. The following guidelines should be followed for packaging and shipping RCCB products:

    • Pack the RCCB products in the original manufacturer's packaging or a similarly durable packaging material to protect the product.
    • Ensure that the package is labeled clearly with the RCCB product name, part number, and the shipping address.
    • Securely seal the package with tape or other appropriate sealing methods.
    • Ship the package through an appropriate shipping service that provides tracking.
    • Provide the tracking number to the customer.
    Quality 16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)