    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    UKCA 30mA-300mA Residual Current Circuit Breaker RCCB Type EV 10kA

    Residual Current Circuit Breaker RCCB type EV 10kA Ultimate Short-Circuit Breaking Capacity


    VKL11F Residual Current Operated Circuit Breaker

    Type F EV

    1.General

    1.1Function

    Residual Current Circuit Breaker VKL11F TYPE F EV (RCCB TYPE F EV) is the Type EV RCCB which has been developed specifically for EV charging systems and can detect AC and DC residual currents in accordance with the requirements of EN61008-1 and EN62423(function for detecting smooth DC residual current and a tripping threshold of 6mA )

    The VKL11F RCCB TYPE F EV also detects residual currents with mixed frequencies which is different from 50Hz. Electronic wiring and power electronics are required in electric vehicles for charging purposes. In the event of a fault, these can give rise to smooth DC residual currents and residual currents with mixed frequencies.The VKL11F RCCB TYPE F EV is also short-time delayed and has increased surge current strength. This significantly reduces the risk of faulty tripping.

    1.2 Selection

    Detectable wave form

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC

    residual currents

    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

    Smooth DC 6mA

    smooth DC residual currents (switch-off at max 6 mA)


    1.3 Approvals and certificates :UKCA,CE


    Tripping sensitivity

    30mA - 50Hz sinusoidal AC ; Pulsating DC

    Smooth DC ≥ 6 mA (RDC-PD)

    Tripping time

    short time delayed (G )


    2. Outline and installation dimensions (mm)

    3. Technical parameters

    StandardIEC/EN 61008-1 & EN62423
    Electrical featuresModel No.VKL11F F EV
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n30mA
    DC tripping threshold6mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui500V
    Rated frequency50/60 Hz

    Rated residual making and

    breaking capacity I△m

    500A (In=16A, 25A, 32A, 40A)
    630A(In=63A), 800A(In=80A), 1000A(In=100A)
    Short-circuit current Inc=I△c6000A, 10000A,1500 A

    Rated making and breaking capacity Im

    Peak withstand current

    3 kA (8/20 μs) surge current proof
    Type (wave form of the earth leakage sensed)

    AC, A

    Smooth DC 6mA

    Tripping timeShort time delayed
    break time under I△n

    10ms~300ms

    (G,type)

    Rated impulse withstand voltage(1.2/50) Uimp6kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 55℃
    Storage temperature-40℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom
    StandardEN61008-1 ,EN62423,OVE E8601

    RCCB RDC-PD | Residual Current Circuit Breaker

    Product Description:

    The Residual Current Circuit Breaker (RCCB) is a high-performance electrical safety device designed to protect people and equipment from electrical shocks. It is certified by Inmetro, NF SEMKO, VDE, KEMA, and ISI mark, providing superior safety and reliability. It features a rated operating duration of no more than 1s, a rated frequency of 50/60Hz, a rated operating frequency of 50/60Hz, a rated service impulse withstand voltage of 6kV, making it a reliable and capable device. The RCCB is easy to install and maintain, and it is a reliable and cost-effective solution for ensuring safety in residential, commercial, and industrial settings.

    Features:

    • Product Name: Residual Current Circuit Breaker RCCB
    • Rated Voltage: 240/415V AC
    • Rated Service Impulse Withstand Voltage: 6kV
    • Rated Impulse Withstand Voltage: 4kV
    • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA
    • Rated Frequency: 50/60Hz

    Applications:

    HAROK VKL11 Residual Current Circuit Breaker RCCB type EV is the perfect solution for electrical safety at home. It is widely approved by NF, SEMKO, VDE, KEMA, ISI, CE, and Inmetro. With a minimum order quantity of 5000, the packaging details are paper carton. The delivery time is 4-6 weeks after payment and the payment terms are FOB NINGBO or SHANGHAI. HAROK VKL11 is capable of supplying 100,000 PCS per month. It has a rated operating frequency of 50/60Hz and a rated operating duration of ≤1s. The certificate is CE, ISI, NF, SEMKO, VDE, KEMA and the rated short-circuit breaking capacity is 10kA, and the rated residual operating current is from 30mA to 300mA.

    Customization:

    Residual Current Circuit Breaker RCCB

    Brand Name: HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Certification: NF, SEMKO, VDE, KEMA, ISI, CE

    Minimum Order Quantity: 5000

    Packaging Details: PAPER CARTON

    Delivery Time: 4-6 weeks after payment

    Payment Terms: FOB NINGBO or SHANGHAI

    Supply Ability: 100,000 PCS PER MONTH

    Rated Service Impulse Withstand Voltage: 6kV

    Rated Insulation Voltage: 500V

    Rated Voltage: 240/415V AC

    Certificate: CE, ISI, NF, SEMKO, VDE, KEMA

    Residual Current Circuit Breaker Inmetro

    Our Residual Current Circuit Breaker RCCB features Inmetro certification, guaranteeing the safety of your household with the highest quality.

    Residual Current Circuit Breaker NF SEMKO VDE KEMA

    All our Residual Current Circuit Breaker RCCB products are certified with NF, SEMKO, VDE, KEMA, making sure that you get the best quality.

    Residual Current Circuit Breaker with ISI mark

    With ISI mark, you can assure that all our Residual Current Circuit Breakers RCCB are up to the highest international safety standards.

    Packing and Shipping:

    Packaging and Shipping for Residual Current Circuit Breaker RCCB

    The Residual Current Circuit Breaker RCCB will be packaged and shipped carefully to ensure its safety during the transit.

    • The product will be securely placed in a cardboard box.
    • The box will be sealed with packaging tape.
    • The box will be labeled with the address and contact information of the recipient.
    • The box will be placed in a larger cardboard box for extra protection.
    • The larger box will be labeled with the same address and contact information.
    • The larger box will be shipped via a reliable shipping service.
    Quality UKCA 30mA-300mA Residual Current Circuit Breaker RCCB Type EV 10kA for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)