Sign In | Join Free | My himfr.com
Home > Residual Current Circuit Breaker RCCB >

CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay

Yueqing Vorax Electric CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay from wholesalers
     
    Buy cheap CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay from wholesalers
    • Buy cheap CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay from wholesalers
    • Buy cheap CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay from wholesalers
    • Buy cheap CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay from wholesalers

    CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay

    CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective time delay for Short-Circuit Protection


    VKL11 Residual Current Circuit Breaker RCCB Type S Selective time delay


    1. General


    1.1 RCCB Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 RCCB Selection

    Detectable wave form

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.


    1.3 RCCB Approvals and certificates

    We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity

    10mA - precision instrument leakage protection and bathroom use.

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

    300mA/500mA - protection against indirect contacts, as well as fire hazard.

    Tripping time

    Instantaneous

    It ensures instantaneous tripping(without time-delay).

    Short time delay ASi

    (High Immunity/ Avoid nuisance tripping &blinding)

    It ensures any tripping at least 10ms.

    Selective

    It ensures total discrimination with a non selective RCD placed downstream.

    CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay


    RCCB | Residual Current Circuit Breaker


    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VKL11
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)AC, A, ASi, S
    break time under I△n

    ≤0.1s(Normal type),

    10ms~300ms(ASi type).

    150ms~500ms(S type)

    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom

    3. RCCB Outline and installation dimensions (mm)


    Product Description:

    The Residual Current Circuit Breaker (RCCB) with ISI mark NF SEMKO VDE KEMA is an innovative electrical protection device that is designed to protect people and property from electric shock and fire hazards. It is designed to detect and respond quickly to dangerous leakage currents, and it has a rated service short-circuit breaking capacity of 6kA, a rated impulse withstand voltage of 4kV, a rated operating frequency of 50/60Hz, a rated service impulse withstand voltage of 6kV, and a rated insulation voltage of 500V. This RCCB has been rigorously tested for safety and reliability and is approved by ISI mark NF SEMKO VDE KEMA. It provides reliable protection against damage or injury caused by electric shock or fire due to earth leakage current, overload current, and short-circuit current. The RCCB is suitable for residential, commercial, and industrial applications and is one of the most reliable and dependable circuit protection devices on the market.

    Features:

    • Product Name: Residual Current Circuit Breaker RCCB
    • Certification: NF SEMKO VDE KEMA
    • Type: Residual Current Circuit Breaker type S
    • Rated Operating Duration: ≤1s
    • Rated Voltage: 240/415V AC
    • Rated Operating Frequency: ≤0.2times/h
    • Rated Residual Current Off-Time: ≤0.1s
    • Rated Residual Operating Current: 30mA-300mA

    Applications:

    HAROK VKL11 Residual Current Circuit Breaker (RCCB) is a reliable product certified by NF, SEMKO, VDE, KEMA, ISI, and CE. The minimum order quantity is 5000 pieces and the packaging is paper carton. The delivery time is 4-6 weeks after payment and the payment terms are FOB NINGBO or SHANGHAI. The rated current is 30mA-100mA and the rated service short-circuit breaking capacity is 6kA. The rated voltage is 240/415V AC and the rated frequency is 50/60Hz. Moreover, the rated insulation voltage is 500V. This product is ideal for applications requiring Residual Current Circuit Breaker type EV with an ISI mark, Residual Current Circuit Breaker NF SEMKO VDE KEMA, and other related applications, ensuring a high supply ability of 100,000 PCS per month.

    Technical Parameters:

    ParameterValue
    CertificationNF SEMKO VDE KEMA
    Rated Current30mA-300mA
    Rated Operating Frequency50/60Hz
    Rated Ultimate Short-Circuit Breaking Capacity10kA
    Rated Insulation Voltage500V
    Rated Service Impulse Withstand Voltage6kV
    Rated Service Short-Circuit Breaking Capacity10kA
    Rated Impulse Withstand Voltage4kV
    Rated Short-Circuit Breaking Capacity10kA
    Rated Frequency50/60Hz

    Customization:

    Residual Current Circuit Breaker RCCB with ISI mark
    • Brand Name: HAROK
    • Model Number: VKL11
    • Place of Origin: CHINA
    • Certification: NF, SEMKO, VDE, KEMA, ISI, CE
    • Minimum Order Quantity: 5000
    • Packaging Details: PAPER CARTON
    • Delivery Time: 4-6 weeks after payment
    • Payment Terms: FOB NINGBO or SHANGHAI
    • Supply Ability: 100,000 PCS PER MONTH
    • Rated Service Short-Circuit Breaking Capacity: 10kA
    • Rated Ultimate Short-Circuit Breaking Capacity: 10kA
    • Rated Service Impulse Withstand Voltage: 6kV
    • Rated Impulse Withstand Voltage: 4kV

    Packing and Shipping:

    Packaging and Shipping for Residual Current Circuit Breaker (RCCB)

    At our company, we package RCCBs in sturdy cardboard boxes with foam cushioning to protect against shock and vibration during transportation. Each box will contain one RCCB unit.

    We use reliable and secure shipping services to deliver our products to customers around the world. Our shipments are always tracked and insured in case of any damage or theft.

    Our company also offers custom packaging and shipping services for larger orders. We understand that your needs may vary, and we are committed to providing quality services to meet your specific requirements.

    Quality CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)