Sign In | Join Free | My himfr.com
Home > UL489 Circuit Breaker >

VK007 DC Circuit Breaker (MCBs) UL489 Circuit Breaker, Thermal-Magnetic Trip Type, Overload And Short-Circuit Protection

Yueqing Vorax Electric CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap VK007 DC Circuit Breaker (MCBs) UL489 Circuit Breaker, Thermal-Magnetic Trip Type, Overload And Short-Circuit Protection from wholesalers
     
    Buy cheap VK007 DC Circuit Breaker (MCBs) UL489 Circuit Breaker, Thermal-Magnetic Trip Type, Overload And Short-Circuit Protection from wholesalers
    • Buy cheap VK007 DC Circuit Breaker (MCBs) UL489 Circuit Breaker, Thermal-Magnetic Trip Type, Overload And Short-Circuit Protection from wholesalers
    • Buy cheap VK007 DC Circuit Breaker (MCBs) UL489 Circuit Breaker, Thermal-Magnetic Trip Type, Overload And Short-Circuit Protection from wholesalers

    VK007 DC Circuit Breaker (MCBs) UL489 Circuit Breaker, Thermal-Magnetic Trip Type, Overload And Short-Circuit Protection

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VK007 DC
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    • Product Details
    • Company Profile

    VK007 DC Circuit Breaker (MCBs) UL489 Circuit Breaker, Thermal-Magnetic Trip Type, Overload And Short-Circuit Protection

    VK007 DC Circuit Breaker


    1. General

    1.1 Standard: IEC/EN 60947-2, RoHS;

    1.2 Rated voltage up to 1000V, Rated current up to 63A;

    1.3 Protection of circuits against overload currents;

    1.4 Protection of circuits against short- circuit currents;

    1.5 VF008 DC circuit-breakers are used in communication systems and PV DC systems.


    2. Features

    2.1 Excellent breaking capacity

    2.2 Double connection function of lead wire and bus bar

    2.3 Stored energy operation, fast closing, long service life

    2.4 Convenient installation, disassembly

    2.5 Contact on-off indication, higher security

    2.6 Green environmental protection and energy saving


    3. Operating conditions

    3.1 Ambient temperature: -35℃ - + 70℃(Refer to 4.3)

    3.2 The atmosphere condition: ≤95%

    3.3 Pollution degree: ll

    3.4 Altitude: ≤2000m(if exceed 2000m,Refer to4.4)


    4. Technical data


    4.1 Classification

    4.1.1 Rate Current In: 1A, 2A, 3A, 4A, 6A, 10A, 13A, 16A, 20A, 25A, 32A. 40A, 50A, 63A

    4.1.2 Number of poles: 1P, 2P, 4P

    4.1.3 Tripping curves: C Type, (7-10)In


    4.2 Parameters

    4.2.1 Rated breaking capacity Icu

    Rated current In (A)Number of polesRated voltage Ue (V)Rated breaking capacity Icu (A)
    1-6312506000
    25006000
    410006000

    4.2.2 Electrical and mechanical life

    a. Electrical life: >1500

    b. Mechanical life: >20,000

    4.2.3 Rated impulse withstand voltage Uimp: 4KV

    4.2.4 (28-32)℃ ambient temperature over-current protection features.

    TestTest current

    Initial

    state

    Time limit for tripping or not tripping

    Expected

    result

    Remark
    a1.05InCold statet≤1hNot tripping
    b1.30InRight after test number at<1hTrippingThe current is rising within 5s
    c7InCold statet≤0.2sNot tripping
    d10InCold statet<0.1sTripping

    Note: The terminology”Cold state”means that the test is performed at the base calibration temperature with no load prior to the test.


    4.3 Temperature derating

    Rated current (A)Temperature compensation coefficient under various operational temperature.
    -35℃-30℃

    -20℃


    -10℃


    0℃


    10℃


    20℃


    30℃


    40℃


    50℃


    60℃


    70℃


    11.31.261.231.191.151.111.0510.960.930.880.83
    22.62.522.462.382.282.22.0821.921.861.761.66
    33.93.783.693.573.423.33.1232.882.792.642.49
    45.25.044.924.764.564.44.1643.843.763.523.32
    67.87.567.387.146.846.66.2465.765.645.284.98
    1013.212.712.51211.511.110.6109.69.38.98.4
    1317.1616.5116.2515.614.9514.4313.781312.4812.0911.5710.92
    1621.1220.482019.218.417.7616.961615.3614.8814.2413.44
    2026.425.625242322.221.22019.218.617.816.8
    25333231.253028.7527.7526.5252423.2522.2521
    3242.5641.284038.7237.1235.5233.933230.7229.7628.1626.88
    4053.251.2504846.444.842.44038.437.235.633.6
    506765.56360.5585653504846.54441.5
    6383.7981.980.0176.8673.7170.5666.786360.4858.955.4452.29

    4.4 Altitude derating

    Tripping typeRated current In (A)Current correction factorFor example
    ≤20002000~3000m≥3000m
    C

    1, 2, 3, 4, 6, 10,

    13, 16, 20, 32, 40, 50, 63

    10.90.8

    Rated current of 10A products rated

    current derating 2500m: 0.9×10=9A


    4.5 Curves shown in Figure 1

    4.6 Wiring: Apply to 25 mm wire connection terminals Tightening torque 2.5N·m

    Rated current In (A)

    Copper wire nominal

    cross sectional area(mm²)

    1~61
    101.5
    13, 16, 202.5
    254
    326
    40, 5010
    6316

    4.7 Each pole power consumption of the circuit breaker

    Rated current In (A)

    Copper wire nominal

    cross sectional area(mm²)

    1~61
    101.5
    13, 16, 202.5

    4.8 DC application wiring diagram shown in Figure 2

    Wiring diagram description:

    1. 〇+Positive 〇-Negative

    2. L+ Load positive L- Load negative

    3. Prohibit power reversed

    4. Rated voltage: 1P: 250V, 2P: 500V, 4P: 1000V

    5. Strictly forbidden to remove the four poles products of sealing plug wiring operation.


    5. Overall and mounting dimensions (mm)

    Product Description:

    UL489 Circuit Breaker is a top-notch mini circuit breaker with a wide range of rated current options from 1A to 63A, and insulation voltage of 500V. It offers excellent protection from overload and short-circuit. It meets the highest safety and quality standards, certified by CE, SAA, SEMKO, NF and other certifications. The protection degree is IP20.

    UL489 Circuit Breaker is an ideal choice for modern households and commercial applications, providing reliable, safe and user-friendly circuit protection that is trusted by millions of users worldwide.


    Features:

    • Product Name: UL489 Circuit Breaker
    • Number of Poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P
    • Insulation voltage Ui: 500V
    • Mechanical life: 20,000
    • Storage temperature: -25℃ To 70℃
    • Rated Current: 1A, 2A, 3A, 4A, 6A, 10A, 15A, 16A, 20A, 25A, 30A, 32A, 40A, 45A, 50A, 60A, 63A
    • MCB: Mini Circuit breaker

    Applications:

    HAROK UL489 Circuit Breaker is a must-have device in various electrical systems that limit the current and prevent overload and short circuit. It is designed with a thermal-magnetic trip type and rated current of 1A, 2A, 3A, 4A, 6A, 10A, 15A, 16A, 20A, 25A, 30A, 32A, 40A, 45A, 50A, 60A, 63A. It is made of high-quality materials and has a mechanical life of 20,000. This Mini Circuit Breaker (MCB) is certified by UL489 and its reference temperature for setting of thermal element is 30℃. It comes in various models such as VF001, VF002, VF003, VK007, VA007, VF008, and VK009. HAROK UL489 Circuit Breaker is a reliable and efficient device that provides protection for the entire electrical system.


    Technical Parameters:

    PropertyData
    Product NameUL489 Circuit Breaker
    Mini Circuit breakermcb
    Number of Poles1P, 1P+N, 2P, 3P, 3P+N, 4P
    Frequency Rating50/60 Hz
    Rated voltage Ue120V, 230/400V ~ 240/415V
    Protection degreeIP20
    Mounting TypeOn DIN Rail EN 60715 (35mm) By Means Of Fast Clip Device
    Reference temperature for setting of thermal element30℃
    Operating Temperature-5℃ To 40℃
    Storage temperature-25℃ To 70℃
    CertificateCE, SAA, SEMKO, NF

    Customization:

    Product Name: UL489 Circuit Breaker

    Brand Name: HAROK

    Model Number: VF001, VF002, VF003, VK007, VA007, VF008, VK009

    Place of Origin: CHINA

    Operating Temperature: -5℃ To 40℃

    Trip Type: Thermal-Magnetic

    Mechanical life: 20,000

    Thermo-magnetic release characteristic: B, C, D

    HAROK UL489 Circuit Breaker is a Mini Circuit Breaker (MCB) which is used to protect electrical circuits from overloads and short circuits. It is designed with advanced technology that provides excellent performance, with operating temperature ranging from -5℃ to 40℃. It has a trip type of Thermal-Magnetic and a mechanical life of 20,000. It is available with thermo-magnetic release characteristics of B, C, and D.


    Packing and Shipping:

    Packaging and Shipping for UL489 Circuit Breaker

    The UL489 Circuit Breaker is shipped in a box, with the following materials:

    • Box with UL489 Circuit Breaker
    • Instruction manual
    • Installation screws and hardware
    • Safety goggles and gloves
    • Protective padding

    The box should be securely sealed before being shipped to the customer.


    Quality VK007 DC Circuit Breaker (MCBs) UL489 Circuit Breaker, Thermal-Magnetic Trip Type, Overload And Short-Circuit Protection for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)