Sign In | Join Free | My himfr.com
Home > RCD TYPE B >

High immunity Residual Current Device Type B

    Buy cheap High immunity Residual Current Device Type B from wholesalers
     
    Buy cheap High immunity Residual Current Device Type B from wholesalers
    • Buy cheap High immunity Residual Current Device Type B from wholesalers
    • Buy cheap High immunity Residual Current Device Type B from wholesalers
    • Buy cheap High immunity Residual Current Device Type B from wholesalers

    High immunity Residual Current Device Type B

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : CE, CB, NF, ISI, SEMKO
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    High immunity Residual Current Device Type B

    High immunity Residual Current Device Type B

    • General

    1.1 Function

    VKL11B RCD and VKL11B+ RCD is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

    Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

    Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

    They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.


    1.2 Selection

    Detectable wave form

    Type B High immunity Residual Current Device Type B

    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

    Type B+ High immunity Residual Current Device Type BHigh immunity Residual Current Device Type B

    Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

    Tripping sensitivity

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

    protection against indirect contacts;

    300mA - protection against indirect contacts, as well as fire hazard.

    Tripping time

    Instantaneous It ensures instantaneous tripping(without time-delay).

    Short time delay

    Selective (time delay)


    1.3 Approvals and certificates


    • Technical parameters
    TypeBB+
    Electrical
    Design according toIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    VDE 0664-400
    Current test marks as printed onto the device
    Rated voltage Un

    2P: 230/240V AC

    4P: 400/415V AC

    Rated frequency fn50/60Hz
    Mode of operation

    "A type functionality: voltage independent

    B and B+ type functionality: voltage dependent"

    Operation voltage electronic50 – 264V AC
    Voltage range test circuit

    2P: 184 – 264V AC

    4P: 184 – 440V AC

    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A

    Rated residual

    operating

    current I△n

    Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    S- selective100mA, 300mA, 500mA100mA, 300mA
    SensitivityAlternating, pulsed and smooth direct currents
    High frequency up to 1 kHZHigh frequency up to 20kHZ
    Rated insulation voltage Ui500 V
    Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
    Rated conditional short-circuit current Inc10 kA
    Rated making and breaking capacity Im1500 A
    Peak withstand current

    3 kA (8/20 μs) surge current proof

    5 kA (8/20 μs) surge current proof for type S

    Electrical isolation> 4 mm contact space

    Maximum back-up fuse

    In = 16-100A

    Short circuit and overload protection

    100 A gG/gL

    Endurance

    (operating cycles)

    electrical components≥ 2000
    mechanical components≥ 4000
    Mechanical
    Degree of protectionIP20
    Upper and lower terminalsopen mounted / lift terminals
    Terminal capacity1 - 25 mm2
    Terminal torque2 - 2.5 Nm
    Busbar thickness0.8 - 2 mm
    Operating temperature-25°C ... +55°C
    Storage- and transport temperature-40°C ... +70°C
    Resistance to climatic conditionsIEC/EN 61008
    Contact position indicatormechanical red / green
    Supply possibilitytop or bottom
    Mounting positionany

    • Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)
      • Applications

    3.1 Typical applications that are vulnerable to smooth DC residual currents:

    - Frequency converters with a three-phase connection

    - Medical equipment such as X-ray equipment or CT machines

    - Photovoltaic or UPS systems

    - Connection points (wall boxes, charging stations) for electric vehicles

    - Elevator controllers

    - Pipeline trace heating

    - Test setups in laboratories

    - Construction sites in accordance with BGI 608 information leaflet (Electronic equipment

    on construction sites)

    - Charging stations for battery-powered forklift trucks

    - Cranes of all kinds

    - Mixing plants if relevant loads are connected

    - Variable-speed machine tools, such as milling and grinding machines or lathes


    • Wiring diagrams

    High immunity Residual Current Device Type BHigh immunity Residual Current Device Type B


    • Tripping characteristics

    .B type

    High immunity Residual Current Device Type B


    • Dimensions (mm)

    Product Description:

    The Residual Current Device (RCD) TYPE B is a device designed to protect people from electric shock. It is rated for 30mA current, IP20 protection degree, 500V rated insulation voltage, and 4kV rated impulse withstand voltage. This product is designed to automatically detect and disconnect the electricity supply in milliseconds when an imbalance or leakage of current is detected. It is highly reliable and suitable for most electrical installations. RCD TYPE B is a great choice for protecting your home and family from electric shock and other potential hazards.

    Features:

    • High immunity RCD - Residual Current DeviceTYPE B
    • Rated Insulation Voltage: 500V
    • Operating Temperature: -25℃~+55℃
    • Rated current In: 16A, 25A, 32A, 40A, 63A, 80A, 100A
    • RESIDUAL CURRENT DEVICE - Rated Frequency: 50Hz/60Hz
    • RCD TYPE B

    Applications:

    HAROK VKL11 Residual Current Device (RCD) TYPE B is a high immunity device designed for safety in electrical installations. Certified by CE, CB, NF, ISI, and SEMKO, the RCD TYPE B is a reliable and efficient device that will switch off the electricity in case of an earth leakage fault. With a minimum order quantity of 5,000 and a supply ability of 100,000 pcs per month, the product is extremely accessible and can be delivered in 4-6 weeks after payment, with terms of FOB NINGBO or SHANGHAI. The rated residual operating time is 0.03s, rated residual operating current is 30mA, and the rated storage temperature is -40℃~+70℃. Rated frequency is 50Hz/60Hz and the product is packed in paper carton for secure transportation. HAROK VKL11 RCD TYPE B offers superior protection against electrical shocks, making it an ideal choice for residential and commercial applications.

    Technical Parameters:

    NameParameter
    Rated Frequency50Hz/60Hz
    Protection DegreeIP20
    Rated residual operating current I△n30mA, 100mA, 300mA, 500mA
    Rated Residual Operating Time0.03s
    Rated Insulation Voltage500V
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Storage Temperature-40℃~+70℃
    Operating Temperature-25℃~+55℃
    Rated Residual Operating Current30mA
    Rated Voltage2P: 230/240V AC; 4P: 400/415V AC
    Product NameHigh immunity Residual Current Device (RCD) TYPE B

    Support and Services:

    Technical support and service for Residual Current Device (RCD) TYPE B includes:

    • 24/7 live support
    • Troubleshooting and repair services
    • Replacement parts and accessories
    • Software and firmware updates
    • Product warranty coverage

    Packing and Shipping:

    Packaging and Shipping for Residual Current Device (RCD) TYPE B:


    • The RCD TYPE B should be packed in a box or carton.
    • The box or carton should be sealed and labeled with the product name.
    • The RCD TYPE B should be shipped in a way that avoids damage.
    • The box or carton should be clearly marked with the shipping address, product name, and quantity.
    • The shipping method should be selected according to the product's size and weight.
    Quality High immunity Residual Current Device Type B for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)