Sign In | Join Free | My himfr.com
Home > RCD TYPE B >

Super Immunised Residual Current Device Type B

    Buy cheap Super Immunised Residual Current Device Type B from wholesalers
     
    Buy cheap Super Immunised Residual Current Device Type B from wholesalers
    • Buy cheap Super Immunised Residual Current Device Type B from wholesalers
    • Buy cheap Super Immunised Residual Current Device Type B from wholesalers
    • Buy cheap Super Immunised Residual Current Device Type B from wholesalers

    Super Immunised Residual Current Device Type B

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : CE, CB, NF, ISI, SEMKO
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    Super Immunised Residual Current Device Type B

    Super immunisedResidual Current Device Type B

    • General

    1.1 Function

    VKL11B RCD and VKL11B+ RCD is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

    Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

    Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

    They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.


    1.2 Selection

    Detectable wave form

    Type B Super Immunised Residual Current Device Type B

    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

    Type B+ Super Immunised Residual Current Device Type BSuper Immunised Residual Current Device Type B

    Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

    Tripping sensitivity

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

    protection against indirect contacts;

    300mA - protection against indirect contacts, as well as fire hazard.

    Tripping time

    Instantaneous It ensures instantaneous tripping(without time-delay).

    Short time delay

    Selective (time delay)


    1.3 Approvals and certificates


    • Technical parameters
    TypeBB+
    Electrical
    Design according toIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    VDE 0664-400
    Current test marks as printed onto the device
    Rated voltage Un

    2P: 230/240V AC

    4P: 400/415V AC

    Rated frequency fn50/60Hz
    Mode of operation

    "A type functionality: voltage independent

    B and B+ type functionality: voltage dependent"

    Operation voltage electronic50 – 264V AC
    Voltage range test circuit

    2P: 184 – 264V AC

    4P: 184 – 440V AC

    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A

    Rated residual

    operating

    current I△n

    Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    S- selective100mA, 300mA, 500mA100mA, 300mA
    SensitivityAlternating, pulsed and smooth direct currents
    High frequency up to 1 kHZHigh frequency up to 20kHZ
    Rated insulation voltage Ui500 V
    Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
    Rated conditional short-circuit current Inc10 kA
    Rated making and breaking capacity Im1500 A
    Peak withstand current

    3 kA (8/20 μs) surge current proof

    5 kA (8/20 μs) surge current proof for type S

    Electrical isolation> 4 mm contact space

    Maximum back-up fuse

    In = 16-100A

    Short circuit and overload protection

    100 A gG/gL

    Endurance

    (operating cycles)

    electrical components≥ 2000
    mechanical components≥ 4000
    Mechanical
    Degree of protectionIP20
    Upper and lower terminalsopen mounted / lift terminals
    Terminal capacity1 - 25 mm2
    Terminal torque2 - 2.5 Nm
    Busbar thickness0.8 - 2 mm
    Operating temperature-25°C ... +55°C
    Storage- and transport temperature-40°C ... +70°C
    Resistance to climatic conditionsIEC/EN 61008
    Contact position indicatormechanical red / green
    Supply possibilitytop or bottom
    Mounting positionany

    • Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)
      • Applications

    3.1 Typical applications that are vulnerable to smooth DC residual currents:

    - Frequency converters with a three-phase connection

    - Medical equipment such as X-ray equipment or CT machines

    - Photovoltaic or UPS systems

    - Connection points (wall boxes, charging stations) for electric vehicles

    - Elevator controllers

    - Pipeline trace heating

    - Test setups in laboratories

    - Construction sites in accordance with BGI 608 information leaflet (Electronic equipment

    on construction sites)

    - Charging stations for battery-powered forklift trucks

    - Cranes of all kinds

    - Mixing plants if relevant loads are connected

    - Variable-speed machine tools, such as milling and grinding machines or lathes


    • Wiring diagrams

    Super Immunised Residual Current Device Type BSuper Immunised Residual Current Device Type B


    • Tripping characteristics

    .B type

    Super Immunised Residual Current Device Type B


    • Dimensions (mm)

    Product Description:

    RCD TYPE B Product Overview

    RCD TYPE B is a high-immunity RCD with a protection degree of IP20. It has a rated voltage of 2P: 230/240V AC; 4P: 400/415V AC and a rated storage temperature of -40℃~+70℃. Its rated residual operating current is 30mA, providing additional protection against electric shock.

    The RCD TYPE B is made of high-quality materials, designed to be highly reliable and durable, providing maximum safety against electric shock and other electrical hazards. It is also designed to be easy to install and maintain.

    The RCD TYPE B is ideal for residential and commercial applications, providing reliable and cost-effective protection against electric shock, electric fire hazards, and other electrical hazards. It is also suitable for industrial applications, where it can provide protection against high-power electric shock, electric fire hazards, and other electrical hazards.

    The RCD TYPE B is an excellent choice for any application where safety and reliability are the primary requirements. It is designed to provide maximum protection against electric shock and other electrical hazards, while providing reliable and cost-effective protection.

    Features:

    • Product Name: Residual Current Device TYPE B
    • Protection Degree: IP20
    • Rated Voltage: 2P: 230/240V AC; 4P: 400/415V AC
    • Rated Storage Temperature: -40℃~+70℃
    • Rated residual operating current I△n: 30mA, 100mA, 300mA, 500mA
    • Rated Insulation Voltage: 500V
    • Super immunised Residual Current Device

    Applications:


    HAROK's VKL11 RCD TYPE B is a residual current device that provides protection against electric shocks and fire caused by indirect contact and insulation faults. It is certified by CE, CB, NF, ISI and SEMKO with a minimum order quantity of 5000. It comes in a paper carton and takes 4-6 weeks for delivery after payment. Payment is accepted through FOB NINGBO or SHANGHAI with a supply ability of 100,000 PCS PER MONTH. It has a rated insulation voltage of 500V, protection degree of IP20, rated residual non-operating time of 0.3s, rated frequency of 50Hz/60Hz and rated current of 30mA.


    Technical Parameters:


    ParameterSpecification
    ProductHigh immunity RCD, Super immunised Residual Current Device (RCD)
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Residual Operating Time0.03s
    Rated residual operating current I△n30mA, 100mA, 300mA, 500mA
    Rated Current30mA
    Rated Storage Temperature-40℃~+70℃
    Rated Residual Non-Operating Time0.3s
    Rated Frequency50Hz/60Hz
    Rated Insulation Voltage500V
    Protection DegreeIP20
    Rated conditional short-circuit current Inc10kA

    Customization:


    Residual Current Device Type B HAROK VKL11

    Brand Name: HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Certification: CE, CB, NF, ISI, SEMKO

    Minimum Order Quantity: 5000

    Packaging Details: PAPER CARTON

    Delivery Time: 4-6 weeks after payment

    Payment Terms: FOB NINGBO or SHANGHAI

    Supply Ability: 100,000 PCS PER MONTH

    Operating Temperature: -25℃~+55℃

    Rated Residual Non-Operating Time: 0.3s

    Rated conditional short-circuit current Inc: 10kA

    Product Name: Residual Current Device TYPE B

    Rated Frequency: 50Hz/60Hz


    Packing and Shipping:


    Packaging and Shipping for Residual Current Device TYPE B:

    The Residual Current DeviceTYPE B will be packaged in a sturdy cardboard box and sealed with a waterproof bag. The package will include instructions and safety warnings. The package will be shipped using a reliable courier service, ensuring that it arrives in perfect condition.

    Quality Super Immunised Residual Current Device Type B for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)