Sign In | Join Free | My himfr.com
Home > RCD TYPE B >

VKL11 Residual Current Device RCD TYPE B

    Buy cheap VKL11 Residual Current Device RCD TYPE B from wholesalers
     
    Buy cheap VKL11 Residual Current Device RCD TYPE B from wholesalers
    • Buy cheap VKL11 Residual Current Device RCD TYPE B from wholesalers
    • Buy cheap VKL11 Residual Current Device RCD TYPE B from wholesalers
    • Buy cheap VKL11 Residual Current Device RCD TYPE B from wholesalers

    VKL11 Residual Current Device RCD TYPE B

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : CE, CB, NF, ISI, SEMKO
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VKL11 Residual Current Device RCD TYPE B

    VKL11 Residual Current Device(RCD) TYPE B

    • General

    1.1 Function

    VKL11B RCD and VKL11B+ RCD is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

    Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

    Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

    They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.


    1.2 Selection

    Detectable wave form

    Type B VKL11 Residual Current Device RCD TYPE B

    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

    Type B+ VKL11 Residual Current Device RCD TYPE BVKL11 Residual Current Device RCD TYPE B

    Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

    Tripping sensitivity

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

    protection against indirect contacts;

    300mA - protection against indirect contacts, as well as fire hazard.

    Tripping time

    Instantaneous It ensures instantaneous tripping(without time-delay).

    Short time delay

    Selective (time delay)


    1.3 Approvals and certificates


    • Technical parameters
    TypeBB+
    Electrical
    Design according toIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    VDE 0664-400
    Current test marks as printed onto the device
    Rated voltage Un

    2P: 230/240V AC

    4P: 400/415V AC

    Rated frequency fn50/60Hz
    Mode of operation

    "A type functionality: voltage independent

    B and B+ type functionality: voltage dependent"

    Operation voltage electronic50 – 264V AC
    Voltage range test circuit

    2P: 184 – 264V AC

    4P: 184 – 440V AC

    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A

    Rated residual

    operating

    current I△n

    Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    S- selective100mA, 300mA, 500mA100mA, 300mA
    SensitivityAlternating, pulsed and smooth direct currents
    High frequency up to 1 kHZHigh frequency up to 20kHZ
    Rated insulation voltage Ui500 V
    Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
    Rated conditional short-circuit current Inc10 kA
    Rated making and breaking capacity Im1500 A
    Peak withstand current

    3 kA (8/20 μs) surge current proof

    5 kA (8/20 μs) surge current proof for type S

    Electrical isolation> 4 mm contact space

    Maximum back-up fuse

    In = 16-100A

    Short circuit and overload protection

    100 A gG/gL

    Endurance

    (operating cycles)

    electrical components≥ 2000
    mechanical components≥ 4000
    Mechanical
    Degree of protectionIP20
    Upper and lower terminalsopen mounted / lift terminals
    Terminal capacity1 - 25 mm2
    Terminal torque2 - 2.5 Nm
    Busbar thickness0.8 - 2 mm
    Operating temperature-25°C ... +55°C
    Storage- and transport temperature-40°C ... +70°C
    Resistance to climatic conditionsIEC/EN 61008
    Contact position indicatormechanical red / green
    Supply possibilitytop or bottom
    Mounting positionany

    • Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)
      • Applications

    3.1 Typical applications that are vulnerable to smooth DC residual currents:

    - Frequency converters with a three-phase connection

    - Medical equipment such as X-ray equipment or CT machines

    - Photovoltaic or UPS systems

    - Connection points (wall boxes, charging stations) for electric vehicles

    - Elevator controllers

    - Pipeline trace heating

    - Test setups in laboratories

    - Construction sites in accordance with BGI 608 information leaflet (Electronic equipment

    on construction sites)

    - Charging stations for battery-powered forklift trucks

    - Cranes of all kinds

    - Mixing plants if relevant loads are connected

    - Variable-speed machine tools, such as milling and grinding machines or lathes


    • Wiring diagrams

    VKL11 Residual Current Device RCD TYPE BVKL11 Residual Current Device RCD TYPE B


    • Tripping characteristics

    .B type

    VKL11 Residual Current Device RCD TYPE B


    • Dimensions (mm)

    Product Description:

    The Residual Current Device (RCD) Type B is designed to provide reliable protection against electric shock and fire hazards. It has a rated insulation voltage of 500V, a rated conditional short-circuit current of 10kA, and a rated storage temperature of -40℃~+70℃. This RCD is available in a range of rated currents, including 16A, 25A, 32A, 40A, 63A, 80A, and 100A. It also has a protection degree of IP20.

    The RCD Type B is an essential safety device for electrical systems. It monitors the flow of electricity in the circuit, and trips when an imbalance is detected. This helps to reduce the risk of electric shock and fire caused by faults, and ensures a secure and reliable electrical system.

    The RCD Type B is a reliable and cost-effective solution for protecting against electric shock and fire hazards. Its high rated insulation voltage and short-circuit current, wide range of rated currents and excellent storage temperature make it an ideal choice for any application.

    Features:

    • Product Name: RCD TYPE B
    • Rated Residual Operating Current: 30mA
    • Operating Temperature: -25℃~+55℃
    • Rated Impulse Withstand Voltage: 4kV
    • Rated Frequency: 50Hz/60Hz
    • Rated Residual Operating Currents: 30mA, 100mA, 300mA, 500mA

    Applications:

    HAROK VKL11 Residual Current Device (RCD) Type B is designed for safety protection against electric shock and fire, to detect leakage currents and to disconnect the circuit in case of a fault. It can be used in both domestic and commercial applications. It has a rated frequency of 50Hz/60Hz, operating temperature of -25℃~+55℃, protection degree of IP20, rated current of 30mA, and rated residual non-operating time of 0.3s. Certified by CE, CB, NF, ISI, and SEMKO, it is available with a minimum order quantity of 5000 and packaged in paper carton. Delivery time is 4-6 weeks after payment and FOB NINGBO or SHANGHAI is accepted. The supply ability is up to 100,000 PCS per month.

    Technical Parameters:

    ParametersValues
    Product NameResidual Current Device TYPE B
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Residual Operating Current I△n30mA, 100mA, 300mA, 500mA
    Rated Residual Operating Time0.03s
    Rated Residual Non-Operating Time0.3s
    Rated Frequency50Hz/60Hz
    Rated conditional short-circuit current Inc10kA
    Rated Impulse Withstand Voltage4kV
    Rated Storage Temperature-40℃~+70℃
    Operating Temperature-25℃~+55℃

    Support and Services:

    For RCD TYPE B, technical support and services include:

    • Troubleshooting assistance
    • Software and firmware updates
    • Replacement parts and repair services
    • User manuals and product documentation
    • Maintenance and repair services
    • Training and certification programs

    Packing and Shipping:

    The packaging and shipping of RCD TYPE B products involves several steps:

    • RCD TYPE B products are first placed in a cardboard box.
    • The box is then sealed with tape.
    • A warning label is attached to the box, stating that the product is fragile.
    • The box is then placed in a larger container for shipping.
    • The container is sealed with tape.
    • A label is attached to the container with the address, product information, and other necessary details.
    • The container is then shipped to its destination.
    Quality VKL11 Residual Current Device RCD TYPE B for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)