    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : CE, CB, NF, ISI, SEMKO
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VKL11 Residual Current Device RCD Type B+

    VKL11 Residual Current Device(RCD) Type B+


    1. General


    1.1 Function

    VKL11B RCD and VKL11B+ RCD is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

    Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

    Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

    They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.


    1.2 Selection


    Detectable wave form


    Type B VKL11 Residual Current Device RCD Type B+

    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.


    Type B+ VKL11 Residual Current Device RCD Type B+VKL11 Residual Current Device RCD Type B+

    Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA


    Tripping sensitivity

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;

    300mA - protection against indirect contacts, as well as fire hazard.


    Tripping time

    Instantaneous It ensures instantaneous tripping(without time-delay).

    Short time delay

    Selective (time delay)


    1.3 Approvals and certificates


    RCD | Residual Current Device


    2. Technical parameters


    TypeBB+
    Electrical
    Design according toIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    VDE 0664-400
    Current test marks as printed onto the device
    Rated voltage Un

    2P: 230/240V AC

    4P: 400/415V AC

    Rated frequency fn50/60Hz
    Mode of operation

    "A type functionality: voltage independent

    B and B+ type functionality: voltage dependent"

    Operation voltage electronic50 – 264V AC
    Voltage range test circuit

    2P: 184 – 264V AC

    4P: 184 – 440V AC

    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A

    Rated residual

    operating

    current I△n

    Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    S- selective100mA, 300mA, 500mA100mA, 300mA
    SensitivityAlternating, pulsed and smooth direct currents
    High frequency up to 1 kHZHigh frequency up to 20kHZ
    Rated insulation voltage Ui500 V
    Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
    Rated conditional short-circuit current Inc10 kA
    Rated making and breaking capacity Im1500 A
    Peak withstand current

    3 kA (8/20 μs) surge current proof

    5 kA (8/20 μs) surge current proof for type S

    Electrical isolation> 4 mm contact space

    Maximum back-up fuse

    In = 16-100A

    Short circuit and overload protection

    100 A gG/gL

    Endurance

    (operating cycles)

    electrical components≥ 2000
    mechanical components≥ 4000
    Mechanical
    Degree of protectionIP20
    Upper and lower terminalsopen mounted / lift terminals
    Terminal capacity1 - 25 mm2
    Terminal torque2 - 2.5 Nm
    Busbar thickness0.8 - 2 mm
    Operating temperature-25°C ... +55°C
    Storage- and transport temperature-40°C ... +70°C
    Resistance to climatic conditionsIEC/EN 61008
    Contact position indicatormechanical red / green
    Supply possibilitytop or bottom
    Mounting positionany

    3. Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)


    3.1 Applications

    Typical applications that are vulnerable to smooth DC residual currents:

    - Frequency converters with a three-phase connection

    - Medical equipment such as X-ray equipment or CT machines

    - Photovoltaic or UPS systems

    - Connection points (wall boxes, charging stations) for electric vehicles

    - Elevator controllers

    - Pipeline trace heating

    - Test setups in laboratories

    - Construction sites in accordance with BGI 608 information leaflet (Electronic equipment on construction sites)

    - Charging stations for battery-powered forklift trucks

    - Cranes of all kinds

    - Mixing plants if relevant loads are connected

    - Variable-speed machine tools, such as milling and grinding machines or lathes


    4. Wiring diagrams



    5. Tripping characteristics


    B type


    6. Dimensions (mm)



    Product Description:

    The Super immunised Residual Current Device (RCD) Type B+ is designed to protect people from electrical shock by disconnecting the power supply when it detects a fault current. It is rated for a maximum conditional short-circuit current of 10kA, and is available in rated currents of 16A, 25A, 32A, 40A, 63A, 80A, and 100A, with a rated insulation voltage of 500V. The device also has a protection degree of IP20 and a rated impulse withstand voltage of 4kV, making it an ideal safety solution for a wide range of applications.

    Features:

    • Product Name: RCD TYPE B+
    • Protection Degree: IP20
    • Rated Residual Operating Time: 0.03s
    • Operating Temperature: -25℃~+55℃
    • Rated Storage Temperature: -40℃~+70℃
    • Rated Frequency: 50Hz/60Hz
    • High immunity RCD

    Applications:

    RCD TYPE B+, also known as Super immunised Residual Current Device, is a reliable RESIDUAL CURRENT DEVICE manufactured by HAROK. It is equipped with superior properties like a minimum order quantity of 5000, with a packaging of paper carton, and a delivery time of 4-6 weeks after payment. Moreover, it offers different payment terms such as FOB NINGBO or SHANGHAI, and has a remarkable supply ability of 100,000 PCS PER MONTH. It is certified by CE, CB, NF, ISI, SEMKO, and has a rated conditional short-circuit current Inc of 10kA, and a rated residual operating time of 0.03s. Along with a rated current In of 16A, 25A, 32A, 40A, 63A, 80A, 100A, it also offers an operating temperature of -25℃~+55℃ and a rated insulation voltage of 500V. RCD TYPE B by HAROK is a perfect choice for any safety application as it provides superior resistance against the current leakage.

    Technical Parameters:

    ParameterValue
    Product NameRESIDUAL CURRENT DEVICE, Super immunised Residual Current Device, RCD TYPE B+
    Rated Residual Operating Current I△n30mA, 100mA, 300mA, 500mA
    Rated Voltage (2P)230/240V AC
    Rated Voltage (4P)400/415V AC
    Rated Current16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Storage Temperature-40℃~+70℃
    Rated Current30mA
    Operating Temperature-25℃~+55℃
    Rated Residual Operating Time0.03s
    Rated Conditional Short-circuit Current Inc10kA
    Protection DegreeIP20
    Rated Residual Non-Operating Time0.3s

    Support and Services:

    Technical support and services for RCD TYPE B+ include:

    • 24/7 online customer service support
    • Free technical troubleshooting and problem-solving
    • On-site installation and maintenance
    • Regular software and hardware updates
    • Lifetime warranty

    Packing and Shipping:

    Packaging and Shipping

    RCD TYPE B+ products are shipped in protective packaging to ensure the product remains in the same condition as it was when it left the factory. The packaging materials used for the product may vary depending on the size and weight of the items, but generally speaking, the product is packaged in cardboard boxes with foam inserts.

    Shipping is usually done by an express courier service, such as UPS or FedEx, and the delivery time can vary depending on the destination. The product is tracked and insured for any potential damages during transportation.

    Quality VKL11 Residual Current Device RCD Type B+ for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)