    Brand Name : HAROK
    Model Number : VKL11
    Certification : CE, CB, NF, ISI, SEMKO
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VKL11 RCD Type B

    VKL11 RCD Type B

    • General

    1.1 Function

    VKL11B RCD and VKL11B+ RCD is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

    Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

    Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

    They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.


    1.2 Selection

    Detectable wave form

    Type B

    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

    Type B+

    Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

    Tripping sensitivity

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

    protection against indirect contacts;

    300mA - protection against indirect contacts, as well as fire hazard.

    Tripping time

    Instantaneous It ensures instantaneous tripping(without time-delay).

    Short time delay

    Selective (time delay)


    1.3 Approvals and certificates


    • Technical parameters
    TypeBB+
    Electrical
    Design according toIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    VDE 0664-400
    Current test marks as printed onto the device
    Rated voltage Un

    2P: 230/240V AC

    4P: 400/415V AC

    Rated frequency fn50/60Hz
    Mode of operation

    "A type functionality: voltage independent

    B and B+ type functionality: voltage dependent"

    Operation voltage electronic50 – 264V AC
    Voltage range test circuit

    2P: 184 – 264V AC

    4P: 184 – 440V AC

    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A

    Rated residual

    operating

    current I△n

    Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    S- selective100mA, 300mA, 500mA100mA, 300mA
    SensitivityAlternating, pulsed and smooth direct currents
    High frequency up to 1 kHZHigh frequency up to 20kHZ
    Rated insulation voltage Ui500 V
    Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
    Rated conditional short-circuit current Inc10 kA
    Rated making and breaking capacity Im1500 A
    Peak withstand current

    3 kA (8/20 μs) surge current proof

    5 kA (8/20 μs) surge current proof for type S

    Electrical isolation> 4 mm contact space

    Maximum back-up fuse

    In = 16-100A

    Short circuit and overload protection

    100 A gG/gL

    Endurance

    (operating cycles)

    electrical components≥ 2000
    mechanical components≥ 4000
    Mechanical
    Degree of protectionIP20
    Upper and lower terminalsopen mounted / lift terminals
    Terminal capacity1 - 25 mm2
    Terminal torque2 - 2.5 Nm
    Busbar thickness0.8 - 2 mm
    Operating temperature-25°C ... +55°C
    Storage- and transport temperature-40°C ... +70°C
    Resistance to climatic conditionsIEC/EN 61008
    Contact position indicatormechanical red / green
    Supply possibilitytop or bottom
    Mounting positionany

    • Special features regarding the use of SIQUENCE universal current-sensitive residual current device (Type B and Type B+)
      • Applications

    3.1 Typical applications that are vulnerable to smooth DC residual currents:

    - Frequency converters with a three-phase connection

    - Medical equipment such as X-ray equipment or CT machines

    - Photovoltaic or UPS systems

    - Connection points (wall boxes, charging stations) for electric vehicles

    - Elevator controllers

    - Pipeline trace heating

    - Test setups in laboratories

    - Construction sites in accordance with BGI 608 information leaflet (Electronic equipment

    on construction sites)

    - Charging stations for battery-powered forklift trucks

    - Cranes of all kinds

    - Mixing plants if relevant loads are connected

    - Variable-speed machine tools, such as milling and grinding machines or lathes


    • Wiring diagrams

    VKL11 RCD Type BVKL11 RCD Type B


    • Tripping characteristics

    .B type

    VKL11 RCD Type B


    • Dimensions (mm)

    Product Description:

    The RESIDUAL CURRENT DEVICE (RCD) TYPE B is a super immunised Residual Current Device that offers exceptional protection against electric shock and fire from earth leakage. This comprehensive safety system is suitable for a wide variety of applications, and features an operating temperature range of -25℃ to +55℃, a rated residual non-operating time of 0.3s, a rated voltage of 2P: 230/240V AC and 4P: 400/415V AC, and a rated current of 30mA. The RCD TYPE B provides superior safety and reliability, making it the perfect choice for both commercial and residential applications.

    Features:

    • Product Name: RCD TYPE B
    • Rated Residual Operating Current: 30mA
    • Rated Residual Non-Operating Time: 0.3s
    • Protection Degree: IP20
    • Rated current In: 16A, 25A, 32A, 40A, 63A, 80A, 100A
    • Rated conditional short-circuit current Inc: 10kA
    • Super immunised Residual Current Device

    Applications:

    High Immunity RCD TYPE B by HAROK

    HAROK's RCD TYPE B offers superior protection for electrical systems and appliances. Certified by CE, CB, NF, ISI, and SEMKO, it has a minimum order quantity of 5000 and is packaged in a paper carton for easy delivery. With a delivery time of 4-6 weeks after payment, it is available through FOB NINGBO or SHANGHAI with a supply capacity of 100,000 PCS PER MONTH. It has a rated current of 16A, 25A, 32A, 40A, 63A, 80A, and 100A, with a rated residual operating current of 30mA and a rated conditional short-circuit current of 10kA. HAROK's RCD TYPE B is the perfect choice for high immunity protection.

    Technical Parameters:

    ParameterValue
    Product NameRCD TYPE B
    Rated Voltage2P: 230/240V AC; 4P: 400/415V AC
    Rated Current30mA
    Rated Conditional Short-Circuit Current Inc10kA
    Rated Impulse Withstand Voltage4kV
    Rated Residual Operating Time0.03s
    Rated Current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Operating Temperature-25℃~+55℃
    Rated Residual Non-Operating Time0.3s
    Rated Residual Operating Current I△n30mA, 100mA, 300mA, 500mA

    Customization:

    RESIDUAL CURRENT DEVICE TYPE B

    Brand Name: HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Certification: CE, CB, NF, ISI, SEMKO

    Minimum Order Quantity: 5000

    Packaging Details: PAPER CARTON

    Delivery Time: 4-6 weeks after payment

    Payment Terms: FOB NINGBO or SHANGHAI

    Supply Ability: 100,000 PCS PER MONTH

    Super immunised Residual Current Device Type B (RCD TYPE B)

    Rated Residual Non-Operating Time: 0.3s

    Rated Residual Operating Time: 0.03s

    Rated Storage Temperature: -40℃~+70℃

    Rated Impulse Withstand Voltage: 4kV

    Operating Temperature: -25℃~+55℃

    Packing and Shipping:

    Packaging and Shipping

    RCD TYPE B is shipped in a cardboard box with a polyethylene bag inside for protection. The box is packaged in a larger cardboard box for transport. The dimensions of the box are 11.5 cm x 9.5 cm x 6.5 cm. The weight of the package is approximately 0.3 kg.