Sign In | Join Free | My himfr.com
Home > RCD TYPE B >

Super Immunised RCD Type B

    Buy cheap Super Immunised RCD Type B from wholesalers
     
    Buy cheap Super Immunised RCD Type B from wholesalers
    • Buy cheap Super Immunised RCD Type B from wholesalers
    • Buy cheap Super Immunised RCD Type B from wholesalers
    • Buy cheap Super Immunised RCD Type B from wholesalers

    Super Immunised RCD Type B

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : CE, CB, NF, ISI, SEMKO
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    Super Immunised RCD Type B

    Super immunisedRCD Type B

    • General

    1.1 Function

    VKL11B RCD and VKL11B+ RCD is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

    Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

    Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

    They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.


    1.2 Selection

    Detectable wave form

    Type B

    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

    Type B+

    Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

    Tripping sensitivity

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

    protection against indirect contacts;

    300mA - protection against indirect contacts, as well as fire hazard.

    Tripping time

    Instantaneous It ensures instantaneous tripping(without time-delay).

    Short time delay

    Selective (time delay)


    1.3 Approvals and certificates


    • Technical parameters
    TypeBB+
    Electrical
    Design according toIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    VDE 0664-400
    Current test marks as printed onto the device
    Rated voltage Un

    2P: 230/240V AC

    4P: 400/415V AC

    Rated frequency fn50/60Hz
    Mode of operation

    "A type functionality: voltage independent

    B and B+ type functionality: voltage dependent"

    Operation voltage electronic50 – 264V AC
    Voltage range test circuit

    2P: 184 – 264V AC

    4P: 184 – 440V AC

    Rated current In40A

    Rated residual

    operating

    current I△n

    Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    S- selective100mA, 300mA, 500mA100mA, 300mA
    SensitivityAlternating, pulsed and smooth direct currents
    High frequency up to 1 kHZHigh frequency up to 20kHZ
    Rated insulation voltage Ui500 V
    Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
    Rated conditional short-circuit current Inc10 kA
    Rated making and breaking capacity Im1500 A
    Peak withstand current

    3 kA (8/20 μs) surge current proof

    5 kA (8/20 μs) surge current proof for type S

    Electrical isolation> 4 mm contact space

    Maximum back-up fuse

    In = 16-100A

    Short circuit and overload protection

    100 A gG/gL

    Endurance

    (operating cycles)

    electrical components≥ 2000
    mechanical components≥ 4000
    Mechanical
    Degree of protectionIP20
    Upper and lower terminalsopen mounted / lift terminals
    Terminal capacity1 - 25 mm2
    Terminal torque2 - 2.5 Nm
    Busbar thickness0.8 - 2 mm
    Operating temperature-25°C ... +55°C
    Storage- and transport temperature-40°C ... +70°C
    Resistance to climatic conditionsIEC/EN 61008
    Contact position indicatormechanical red / green
    Supply possibilitytop or bottom
    Mounting positionany

    • Special features regarding the use of SIQUENCE universal current-sensitive residual current device (Type B and Type B+)
      • Applications

    3.1 Typical applications that are vulnerable to smooth DC residual currents:

    - Frequency converters with a three-phase connection

    - Medical equipment such as X-ray equipment or CT machines

    - Photovoltaic or UPS systems

    - Connection points (wall boxes, charging stations) for electric vehicles

    - Elevator controllers

    - Pipeline trace heating

    - Test setups in laboratories

    - Construction sites in accordance with BGI 608 information leaflet (Electronic equipment

    on construction sites)

    - Charging stations for battery-powered forklift trucks

    - Cranes of all kinds

    - Mixing plants if relevant loads are connected

    - Variable-speed machine tools, such as milling and grinding machines or lathes


    • Wiring diagrams

    Super Immunised RCD Type BSuper Immunised RCD Type B


    • Tripping characteristics

    .B type

    Super Immunised RCD Type B


    • Dimensions (mm)

    Product Description:

    RCD TYPE B is a Super immunised Residual Current Device that has been rated to provide superior protection. It is designed with a Rated Residual Operating Current of 30mA, 100mA, 300mA and 500mA, and a Rated Voltage of 2P: 230/240V AC and 4P: 400/415V AC. The Rated Residual Operating Time for RCD TYPE B is 0.03s, and it has a Rated Current of 16A, 25A, 32A, 40A, 63A, 80A and 100A.

    This product is designed to provide superior protection for electrical circuits and equipment, and it is essential for the reliable operation of the electrical system in any residential, commercial or industrial environment. It is a reliable and cost-effective solution that can help reduce the risk of fire and electrical shock, and it is highly recommended for use in any environment.

    Features:

    • Product Name: RCD TYPE B
    • High immunity RCD, RESIDUAL CURRENT DEVICE, Super immunised Residual Current Device
    • Rated Residual Operating Time: 0.03s
    • Rated Voltage: 2P: 230/240V AC; 4P: 400/415V AC
    • Rated residual operating current I△n: 30mA, 100mA, 300mA, 500mA
    • Rated Current: 30mA
    • Operating Temperature: -25℃~+55℃

    Applications:

    HAROK's RCD TYPE B (Residual Current Device) with model number VKL11 is a reliable and stable product, certified with CE, CB, NF, ISI, and SEMKO standards. It has a minimum order quantity of 5000 and comes in a paper carton packaging. The delivery time is 4-6 weeks after payment, and the payment terms are FOB NINGBO or SHANGHAI. The supply ability is 100,000 PCS PER MONTH. The rated conditional short-circuit current inc is 10kA and the rated voltage is 2P: 230/240V AC; 4P: 400/415V AC. The rated residual operating current I△n is 30mA, 100mA, 300mA, 500mA, and the rated insulation voltage is 500V.

    Technical Parameters:

    ParameterValue
    Product NameHigh immunity RCD, Super immunised Residual Current Device, TYPE B
    Rated Voltage2P: 230/240V AC; 4P: 400/415V AC
    Rated Current30mA
    Rated Residual Operating Current30mA
    Rated Residual Operating Time0.03s
    Rated Residual Non-Operating Time0.3s
    Protection DegreeIP20
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated conditional short-circuit current Inc10kA
    Rated Impulse Withstand Voltage4kV

    Support and Services:

    Technical Support and Service for RCD TYPE B:

    • 24/7 technical support
    • Access to technical documentation library
    • Software upgrades
    • Hardware repair and maintenance services
    • Remote diagnostic and troubleshooting services
    • On-site technical assistance

    Packing and Shipping:

    The RCD TYPE B should be securely packaged, labeled, and shipped in accordance with applicable regulations and standards. The packaging should include the following:

    • Instructions for installation, operation, and maintenance
    • Product warranty information
    • Appropriate labels for hazard warning and handling
    • Corrosion protection such as VCI (vapor corrosion inhibitors) or other methods as required
    • Shock and vibration protection
    • Moisture protection
    • Appropriate outer packaging, such as cardboard boxes or crates, depending on the size of the shipment
    Quality Super Immunised RCD Type B for sale