Sign In | Join Free | My himfr.com
Home > RCBO Type A >

VDL006 Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50A RCBO Type A

Yueqing Vorax Electric CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap VDL006 Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50A RCBO Type A from wholesalers
     
    Buy cheap VDL006 Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50A RCBO Type A from wholesalers
    • Buy cheap VDL006 Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50A RCBO Type A from wholesalers
    • Buy cheap VDL006 Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50A RCBO Type A from wholesalers
    • Product Details
    • Company Profile

    VDL006 Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50A RCBO Type A

    RCBO | Residual Current Operated Circuit Breaker with over-current protection


    VDL006 Residual Current Operated Circuit Breaker with over-current protection

    (MCB sized 1 module with switched neutral)


    1. General


    VDL006 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.


    2. Technical parameters


    2.1 The tripping characteristic curves are as shown below.


    2.2 Basic parameters


    StandardIEC/EN 61009-1
    Main SpecificationsModel No.VDL006
    Rated current In

    6A, 10A, 16A, 20A, 25A, 32A, 40A

    Classified by Type of Instantaneous TrippingType B: (3 ~ 5) In, Type C: (5 ~ 10) In
    Poles1P + N
    Type (wave form of the earth leakage sensed)Type AC, Type A
    Mechanical featuresRated voltage UeAC240V
    Frame size rated current In40A
    Rated residual operating current I△n10mA, 30mA, 100mA, 300mA
    Rated residual non-operating current I△no5mA, 15mA, 50mA, 150mA
    Rated short-circuit breaking capacity Icn

    3000A, 4500A, 6000A

    Rated residual making and

    breaking capacity I△m

    500A
    Electrical life2,000
    Mechanical life2,000
    Rated impulse withstand voltage Uimp4000V
    ConnectionFrom top and bottom, from bottom and top

    2.3 The residual current breaking times


    In (A)I△n (A)Breaking time when the residual current assumes the following values (s)
    I△n2I△n5I△n5A, 10A, 20A, 50A, 100A, 200A, 500A(a)I△t(b)
    6~400.01, 0.03, 0.1, 0.30.10.050.040.040.04

    a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

    B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.


    2.4 The over-current protection characteristics


    No.Rated current In (A)Initial stateTest current (A)Specified time (t)Expected resultRemarks
    a6 ~ 40Cold state1.13 Int ≥ 1hNon-tripping
    bImmediately after sequence a1.45 Int < 1hTrippingIncrease to the specified current within 5s after test item a.
    cCold state2.55 In1s < t < 60sTripping
    dCold state3 Int ≥ 0.1sNon-trippingType B
    5 Int < 0.1sTripping
    5 Int ≥ 0.1sNon-trippingType C
    10 Int < 0.1sTripping

    3. Outline and installation dimensions (mm)


    Product Description:

    Introducing RCBO Type A – a Residual Current Operated Circuit Breaker with over-current protection. This circuit breaker is designed to protect you from electric shock caused by the leakage of electricity. It has a frame size rated current of Inm: 50A and a rated residual current operating time of ≤0.1s. It also features rated residual operating current I△n of 0.01A, 0.03A, 0.1A, 0.3A, and rated residual non-operating current I△no of 0.005A, 0.015A, 0.05A, 0.15A. With a rated residual current on-state of ≤0.2mA, RCBO Type A is the perfect choice for protecting your home from electric shock.

    RCBO Type A is the ideal circuit breaker for anyone looking for a reliable and effective residual current operated circuit breaker with over-current protection. It is the perfect choice for those who need a circuit breaker that can withstand the harsh conditions of an electrical environment. With its frame size rated current of Inm: 50A and its rated residual current operating time of ≤0.1s, RCBO Type A ensures that you are always safe and sound.

    The RCBO Type A also features rated residual operating current I△n of 0.01A, 0.03A, 0.1A, 0.3A, and rated residual non-operating current I△no of 0.005A, 0.015A, 0.05A, 0.15A. With its rated residual current on-state of ≤0.2mA, the RCBO Type A ensures that you are always protected against electric shock.

    So if you are looking for a reliable, durable, and effective residual current operated circuit breaker with over-current protection, then look no further than RCBO Type A. With its frame size rated current of Inm: 50A and its rated residual current operating time of ≤0.1s, the RCBO Type A provides the ultimate in protection, durability, and reliability.


    Features:

    • Product Name: RCBO Type A
    • Residual Current Operated Circuit Breaker with over-current protection
    • Rated residual non-operating current I△no: 0.005A, 0.015A, 0.05A, 0.15A
    • Rated Frequency: 50/60Hz
    • Mechanical life: 2000
    • Rated Breaking Capacity: 6kA

    Applications:

    HAROK’s RCBO Type A Circuit Breakers provide superior over-current protection for a range of commercial and industrial applications. These circuit breakers are available in eight models, with rated breaking capacities ranging from 6kA to 50A. Models VRL22, VAL003, VKL003, VDL006, VRL11, VRL01, VRL02, VRL03 and VK007LE offer a range of residual operating current I△n of 0.01A, 0.03A, 0.1A, 0.3A and residual current operating time of ≤0.1s. Rated currents include 6A, 10A, 16A, 20A, 25A, 32A, 40A and 50A. This product is the ideal choice for any commercial or industrial application requiring superior Residual Current Operated Circuit Breaker with over-current protection.


    Technical Parameters:

    ParameterValue
    Rated voltage UeAC240V
    Rated short-circuit breaking capacity Icn230/240V 6000A, 10000A; 120V 15000A
    Rated Residual Current Off-state≤0.1mA
    Rated residual non-operating current I△no0.005A, 0.015A, 0.05A, 0.15A
    Rated residual operating current I△n0.01A, 0.03A, 0.1A, 0.3A
    Electrical life2000
    Rated Breaking Capacity6kA
    Frame size rated current Inm50A
    Rated Residual Current Operating Time≤0.1s
    Rated Frequency50/60Hz

    Customization:

    RCBO Type A

    Product Name: RCBO Type A

    Brand Name: HAROK

    Model Number: VRL22, VAL003, VKL003, VDL006, VRL11, VRL01, VRL02, VRL03, VK007LE

    Place of Origin: CHINA

    Rated Residual Current Off-state: ≤0.1mA

    Frame size rated current Inm: 50A

    Rated residual operating current I△n: 0.01A, 0.03A, 0.1A, 0.3A

    Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In

    RCBO Circuit Breaker with Overload Protection

    RCBO combination circuit breakers with overload protection are designed to combine over-current protection and short-circuit protection, as well as providing overload protection. They are suitable for both residential and commercial applications, providing safe and reliable protection for your electrical system. Our RCBO Type A is capable of providing reliable and instant protection against overload current and short-circuits, making it the ideal choice for your home and business.


    Packing and Shipping:

    RCBO Type A products are packaged and shipped using sturdy corrugated cardboard boxes. The boxes are sealed with packing tape and labelled with product information. Before shipping, the boxes are shrink-wrapped for extra protection. The boxes are then placed onto pallets, secured with straps and shrink-wrapped. The pallets can then be picked up by a courier and shipped to the desired destination.



    Quality VDL006 Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50A RCBO Type A for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)