    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    UL1053 Rated Residual Current Device ISI Certificate Non Operating Time 5s

    VKL11 Residual Current Device (RCD) UL1053


    1. General

    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form

    RCD TypeSuitable for electrical networks with
    Pulsated DC currentHarmonicsSwitching surges
    AC CLASSNoNoNo
    A CLASSYesNoNo
    S, ASi CLASSYesYesYes

    A Class RCD may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.



    1.3 Approvals and certificates

    We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity
    10mA - precision instrument leakage protection and bathroom use.
    30mA - additional protection against direct contact.
    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
    300mA/500mA - protection against indirect contacts, as well as fire hazard.
    Tripping time
    Instantaneous
    It ensures instantaneous tripping(without time-delay).
    Short time delay ASi
    (High Immunity/ Avoid nuisance tripping &blinding)
    It ensures any tripping at least 10ms.
    Selective
    It ensures total discrimination with a non selective RCD placed downstream.
    UL1053 Rated Residual Current Device ISI Certificate Non Operating Time 5s



    RCD | Residual Current Device

    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VKL11
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)AC, A, ASi, S
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom



    3. Outline and installation dimensions (mm)

    Product Description:

    Residual Current Device (RCD) is a safety device that protects people and property from serious electric shock caused by earth leakage. It is designed to detect, interrupt and trip the circuit when an earth leakage current is detected. This Residual Current Device is certified with CE, ISI, NF, SEMKO, VDE and KEMA, and has a rated insulation voltage of 500V, a rated residual operating time of 0.1s, a rated operating temperature of -25℃ to +40℃ and a rated current of 30mA. It is also compliant with Residual Current Device standard UL1053. This Residual Current Device is a reliable safety device that can effectively protect people and property from electric shock.

    Features:

    • Product Name: Residual Current Device
    • Rated Humidity: ≤95%RH
    • Rated Impact Endurance Voltage: 2kV
    • Rated Insulation Voltage: 500V
    • Rated Current: 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
    • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA, Inmetro

    Applications:

    The Residual Current Device (RCD) Type EVKL11 from HAROK is a highly dependable and reliable device that can be used in a variety of applications. It is designed to detect and prevent electric shocks from occurring. The RCD is certified by NF, SEMKO, VDE, KEMA, ISI, and CE, and has a minimum order quantity of 1000. It is packaged in paper carton boxes and typically ships in 4-6 weeks after payment. The supply capacity is 100,000 PCs per month. The rated residual operating current is 30mA, 100mA, 300mA, the rated frequency is 50/60Hz, and the rated operating temperature is -25℃~+40℃.

    The Residual Current Device (RCD) Type EVKL11 from HAROK is suitable for use in various environments, including residential, industrial, and commercial settings. It can be used in applications such as grounding, overload protection, and overvoltage protection. It is ideal for protecting electrical circuits from short circuit, overcurrent, and ground fault contaminants. Additionally, it is effective in providing protection against electric shocks, ground fault current, and overcurrent.

    The Residual Current Device (RCD) Type EVKL11 from HAROK is a reliable and safe product that can be used in many different applications. It is designed to detect and prevent electric shocks from occurring. It is certified by NF, SEMKO, VDE, KEMA, ISI, and CE, and is rated with a residual operating current of 30mA-300mA, a frequency of 50/60Hz, and an operating temperature of -25℃~+40℃. It is packaged in paper carton boxes and typically ships in 4-6 weeks after payment.

    Technical Parameters:

    AttributeValue
    Protection ClassIP20
    Product NameResidual Current Device
    CertificateCE, ISI, NF, SEMKO, VDE, KEMA
    Rated Residual Operating Current30mA, 100mA, 300mA
    Rated Residual Operating Time0.1s
    Rated Humidity≤95%RH
    Rated Impulse Withstand Voltage4kV
    Rated Residual Non-Operating Time5s
    Rated Frequency50/60Hz

    Customization:

    Residual Current Device

    Brand Name: HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Certification: NF, SEMKO, VDE, KEMA, ISI, CE

    Minimum Order Quantity: 1000

    Packaging Details: PAPER CARTON

    Delivery Time: 4-6 weeks after payment

    Supply Ability: 100,000 PCS PER MONTH

    Rated Short-Circuit Capacity: 10kA

    Rated Insulation Voltage: 500V

    Rated Voltage: 240/415V AC

    Rated Current: 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A

    Protection Class: IP20

    Residual Current Device Type AC, Type A, Type ASi, Residual Current Device, Residual Current Device Inmetro, HAROK, VKL11

    Packing and Shipping:

    Packaging and Shipping

    The Residual Current Device must be packaged and shipped according to the following guidelines:

    • The Residual Current Device must be packaged securely in a box.
    • The box must be labeled with the Residual Current Device's product name and model number.
    • The box must be sealed and all packing materials must be removed prior to shipping.
    • The Residual Current Device must be shipped via a reputable carrier.
    Quality UL1053 Rated Residual Current Device ISI Certificate Non Operating Time 5s for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)