Sign In | Join Free | My himfr.com
Home > Residual Current Device >

VKL11 ISI Mark Residual Current Device RCD

    Buy cheap VKL11 ISI Mark Residual Current Device RCD from wholesalers
     
    Buy cheap VKL11 ISI Mark Residual Current Device RCD from wholesalers
    • Buy cheap VKL11 ISI Mark Residual Current Device RCD from wholesalers
    • Buy cheap VKL11 ISI Mark Residual Current Device RCD from wholesalers
    • Buy cheap VKL11 ISI Mark Residual Current Device RCD from wholesalers

    VKL11 ISI Mark Residual Current Device RCD

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE, INMETRO
    Delivery Time : 4-6 weeks after payment
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VKL11 ISI Mark Residual Current Device RCD

    VKL11 Residual Current Device (RCD) ISI mark


    1. General

    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form

    RCD TypeSuitable for electrical networks with
    Pulsated DC currentHarmonicsSwitching surges
    AC CLASSNoNoNo
    A CLASSYesNoNo
    S, ASi CLASSYesYesYes

    A Class RCD may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.



    1.3 Approvals and certificates

    We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity
    10mA - precision instrument leakage protection and bathroom use.
    30mA - additional protection against direct contact.
    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
    300mA/500mA - protection against indirect contacts, as well as fire hazard.
    Tripping time
    Instantaneous
    It ensures instantaneous tripping(without time-delay).
    Short time delay ASi
    (High Immunity/ Avoid nuisance tripping &blinding)
    It ensures any tripping at least 10ms.
    Selective
    It ensures total discrimination with a non selective RCD placed downstream.
    VKL11 ISI Mark Residual Current Device RCD



    RCD | Residual Current Device

    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VKL11
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)AC, A, ASi, S
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom



    3. Outline and installation dimensions (mm)

    Product Description:

    Residual Current Device (RCD) is a reliable protection device for domestic and industrial applications. It is certified by the Brazilian Institute of Metrology, Quality and Technology (Inmetro) and is designed to protect people and equipment against electric shock. The RCD features a protection class of IP20, rated voltage of 240/415V AC, rated residual operating current of 30mA to 300mA and rated frequency of 50/60Hz. It provides a high level of safety in accordance with the safety standards and provides a safe and reliable protection from electrical shock. It is designed to detect any fault currents and cut off the power supply in time to prevent any potential electric shock or damage to the equipment.

    Features:

    • Product Name: Residual Current Device
    • Protection Class: IP20
    • Rated Current: 30mA, 100mA, 300mA
    • Rated Voltage: 240/415V AC
    • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA, INMETRO
    • Rated Humidity: ≤95%RH
    • Type: Type AC, Type A, Type ASi

    Applications:

    HAROK VKL11 Residual Current Device is a product that has been certified with Inmetro, NF, SEMKO, VDE, KEMA, ISI, INMETRO and CE. It has a rated current of 16A to 100A, as well as a rated residual operating current of 30mA, 100mA, 300mA and a rated voltage of 240/415V AC. The RCD is available in Type A, AC, ASi, and comes with a minimum order quantity of 1000. It is packed in paper carton and can be delivered within 4-6 weeks after payment. HAROK VKL11 Residual Current Device is reliable and has a supply ability of 100,000 PCS per month.

    Technical Parameters:

    Product NameTechnical Parameters
    Residual Current Device
    • Rated Residual Operating Current: 30mA-300mA
    • Rated Humidity: ≤95%RH
    • Rated Impulse Withstand Voltage: 4kV
    • Rated Short-Circuit Capacity: 10kA
    • Rated Impact Endurance Voltage: 2kV
    • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA, INMETRO
    • Protection Class: IP20
    • Rated Operating Temperature: -25℃~+40℃
    • Residual Current Device Type AC, Type A, Type ASi

    Customization:

    Residual Current Device VKL11 from HAROK

    HAROK's Residual Current Device VKL11 is a reliable device that provides protection against indirect contact. It is certified by NF, SEMKO, VDE, KEMA, ISI, and CE, and is recognized for its safety and quality. It has a minimum order quantity of 1000, and is packaged in a paper carton. Delivery time is 4-6 weeks after payment, and a supply ability of 100,000 pieces per month.

    VKL11 Specifications
    • Brand Name: HAROK
    • Model Number: VKL11
    • Place of Origin: CHINA
    • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA
    • Rated Voltage: 240/415V AC
    • Rated Residual Operating Time: 0.1s
    • Protection Class: IP20

    Packing and Shipping:

    Packaging and Shipping of Residual Current Device

    Residual current device (RCD) must be packaged with a sturdy box and with adequate cushioning material to protect it against shocks, vibration, dust, and moisture during transportation.

    The following instructions must be followed when shipping RCD:

    • Ensure that the RCD is securely fastened in the box.
    • Ensure that the box is properly sealed to prevent water or foreign particles from entering.
    • Attach a label to the box indicating the contents and destination.
    • Ensure that the box is clearly marked with the words “Fragile” and “Handle with Care”.
    • Ensure that the box is properly labelled with the correct address and contact information.
    • Ensure that the package is shipped via a reliable carrier.
    Quality VKL11 ISI Mark Residual Current Device RCD for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)