Sign In | Join Free | My himfr.com
Home > Residual Current Device >

Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage

    Buy cheap Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage from wholesalers
     
    Buy cheap Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage from wholesalers
    • Buy cheap Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage from wholesalers
    • Buy cheap Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage from wholesalers
    • Buy cheap Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage from wholesalers

    Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage

    VKL11 Residual Current Device (RCD) type G short-time delay


    1. General

    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form

    RCD TypeSuitable for electrical networks with
    Pulsated DC currentHarmonicsSwitching surges
    AC CLASSNoNoNo
    A CLASSYesNoNo
    S, ASi CLASSYesYesYes

    A Class RCD may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.



    1.3 Approvals and certificates

    We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity
    10mA - precision instrument leakage protection and bathroom use.
    30mA - additional protection against direct contact.
    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
    300mA/500mA - protection against indirect contacts, as well as fire hazard.
    Tripping time
    Instantaneous
    It ensures instantaneous tripping(without time-delay).
    Short time delay ASi
    (High Immunity/ Avoid nuisance tripping &blinding)
    It ensures any tripping at least 10ms.
    Selective
    It ensures total discrimination with a non selective RCD placed downstream.
    Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage



    RCD | Residual Current Device

    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VKL11
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)AC, A, ASi, S
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 10ms~300ms(G type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom



    3. Outline and installation dimensions (mm)

    Product Description:

    Residual Current Device

    The Residual Current Device Type G is a type of Residual Current Device (RCD) designed for alternating current (AC). It is available in Six types - Type A, Type AC, Type ASi, Type B, Type B+ and Type F - with a rated voltage of 240/415V AC, a rated residual operating current of 30mA to 300mA, a rated current of 16A to 100A and a rated insulation voltage of 500V. It is also designed with a rated operating temperature of -25℃~+40℃, making it ideal for a range of applications and environments.

    The Residual Current Device Type G is designed to protect people from electric shocks and provide protection of equipment from fire and other damages. It works by sensing the magnitude of the current and disconnecting the load when the current is not balanced. It is designed with a high level of accuracy and a quick response time to detect any unbalanced current.

    This Residual Current Device Type G is suitable for a range of applications, including residential and commercial buildings, industrial equipment, and medical equipment. It is also designed to meet the safety and quality standards of Underwriters Laboratories (UL) 1053.

    Features:

    • Product Name: Residual Current Device
    • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA
    • Residual Current Device Type: Type AC, Type A, Type ASi
    • Rated Current: 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
    • Rated Operating Temperature: -25℃~+40℃
    • Rated Impact Endurance Voltage: 2kV

    Applications:

    HAROK VKL11 Residual Current Device Type G is a reliable and safe product for the electrical safety. It is certified by NF, SEMKO, VDE, KEMA, ISI, CE and manufactured with premium materials, ensuring its stable performance. The Rated Humidity is ≤95%RH, the Rated Impulse Withstand Voltage is 4kV, the Rated Operating Temperature is -25℃~+40℃, the Rated Voltage is 240/415V AC. With the minimum order quantity of 1000, the packaging is paper carton. The delivery time is 4-6 weeks after payment and the Supply Ability is 100,000 PCS PER MONTH.

    The HAROK VKL11 Residual Current Device Type G is widely used in the residential, commercial, and industrial places. With its outstanding performance in electrical safety, it is ideal for preventing electrical shock, fire hazard, and other dangerous accidents. It is also a perfect choice for protecting the electrical appliances from over-current, over-voltage, short-circuit and other hazardous conditions.

    HAROK VKL11 is an ideal product for providing reliable electrical safety. It is superior to other similar products in terms of rated voltage, rated current, rated impulse withstand voltage, rated residual non-operating current, rated operating temperature, rated humidity, and other important parameters. With its superior performance, it is the perfect choice for both residential and commercial applications.

    Technical Parameters:

    ParameterSpecification
    Product NameResidual Current Device
    Residual Current Device TypeType G
    Rated Humidity≤95%RH
    Rated Short-Circuit Capacity10kA
    Rated Impulse Withstand Voltage4kV
    Rated Impact Endurance Voltage2kV
    Protection ClassIP20
    Rated Current16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Frequency50/60Hz

    Customized Residual Current Device

    Brand Name: HAROK
    Model Number: VKL11
    Place of Origin: CHINA
    Certification: NF, SEMKO, VDE, KEMA, ISI, CE
    Minimum Order Quantity: 1000
    Packaging Details: PAPER CARTON
    Delivery Time: 4-6 weeks after payment
    Supply Ability: 100,000 PCS PER MONTH

    • Residual Current Device Type G: Rated Residual Operating Current: 30mA, 100mA, 300mA; Rated Short-Circuit Capacity: 10kA; Protection Class: IP20; Certificate: CE, ISI, NF, SEMKO, VDE, KEMA.

    Product Name: Residual Current Device


    Packing and Shipping:


    Packaging and Shipping

    Residual Current Devices (RCDs) should be packaged and shipped with care to ensure that it remains in good condition during transport.

    It is recommended that the RCD is placed in a suitable box that is sufficiently strong to protect the product from physical damage. The box should be clearly labelled with a warning sign, indicating the presence of hazardous components or materials. Additionally, the box should be secured with tape to prevent any accidental opening during transit.

    All shipments should be sent using a reliable courier service, such as FedEx, UPS, or DHL. All packages should also be insured for the full value of the shipment. The shipment should include a tracking number so that the package can be monitored and traced in the event of a delivery delay or loss.


    Quality Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)