VKL11 Residual Current Device RCD Type S Selective Time Delay

    Buy cheap VKL11 Residual Current Device RCD Type S Selective Time Delay from wholesalers
     
    Buy cheap VKL11 Residual Current Device RCD Type S Selective Time Delay from wholesalers
    • Buy cheap VKL11 Residual Current Device RCD Type S Selective Time Delay from wholesalers
    • Buy cheap VKL11 Residual Current Device RCD Type S Selective Time Delay from wholesalers
    • Buy cheap VKL11 Residual Current Device RCD Type S Selective Time Delay from wholesalers

    VKL11 Residual Current Device RCD Type S Selective Time Delay

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VKL11 Residual Current Device RCD Type S Selective Time Delay

    VKL11 Residual Current Device (RCD) type S Selective time delay


    1. General

    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form

    RCD TypeSuitable for electrical networks with
    Pulsated DC currentHarmonicsSwitching surges
    AC CLASSNoNoNo
    A CLASSYesNoNo
    S, ASi CLASSYesYesYes

    A Class RCD may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.



    1.3 Approvals and certificates

    We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity
    10mA - precision instrument leakage protection and bathroom use.
    30mA - additional protection against direct contact.
    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
    300mA/500mA - protection against indirect contacts, as well as fire hazard.
    Tripping time
    Instantaneous
    It ensures instantaneous tripping(without time-delay).
    Short time delay ASi
    (High Immunity/ Avoid nuisance tripping &blinding)
    It ensures any tripping at least 10ms.
    Selective
    It ensures total discrimination with a non selective RCD placed downstream.
    VKL11 Residual Current Device RCD Type S Selective Time Delay



    RCD | Residual Current Device

    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VKL11
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)AC, A, ASi, S
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom



    3. Outline and installation dimensions (mm)

    Product Description:

    Residual Current Device

    Residual Current Device (RCD) is a safety device designed to protect people from electric shock and other potential danger. It can detect the presence of a fault current and quickly disconnect the circuit, so that the fault current is interrupted to protect the safety of people from electric shock.

    This product is certified CE, ISI, NF, SEMKO, VDE, KEMA and has a rated operating temperature of -25°C to +40°C. The rated current is 30mA and the rated short-circuit capacity is 10kA.

    Residual Current Device is an important safety device in electrical system and it is widely used in many places such as industrial plants, office buildings, homes, etc.

    Features:

    • Product Name: Residual Current Device
    • Rated Residual Non-Operating Time: 5s
    • Rated Residual Operating Current: 30mA, 100mA, 300mA
    • Rated Current: 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
    • Rated Residual Operating Time: 0.1s
    • Rated Operating Temperature: -25℃~+40℃
    • Type: AC, A, ASi, B, B+, F

    Applications:

    HAROK VKL11 Residual Current Device is designed to detect and trip on leakage current in electrical wiring systems in order to protect people and other devices from potential electric shock. It is ideal for use in domestic, commercial and industrial applications. The device is certified by NF, SEMKO, VDE, KEMA, ISI, CE and has a minimum order quantity of 1000. Delivery time is 4-6 weeks after payment and the company has a supply ability of 100,000 PCS PER MONTH. The Rated Impulse Withstand Voltage is 4kV.

    The HAROK VKL11 Residual Current Device is available in three types: Type AC, Type A and Type ASi. It has a wide range of applications from domestic to commercial and industrial applications. The device is designed to detect and trip on leakage current and protect people and other devices from potential electric shock. The product comes in a PAPER CARTON packaging and is easy to install and maintain. It is a reliable and cost-effective solution for protecting people and their property from electrical hazards.

    Technical Parameters:

    ParameterValue
    Product NameResidual Current Device
    TypeAC, Type A, Type ASi
    Rated Impulse Withstand Voltage4kV
    Rated Frequency50/60Hz
    Rated Current16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Insulation Voltage500V
    CertificateCE, ISI, NF, SEMKO, VDE, KEMA
    Protection ClassIP20
    Rated Residual Operating Current30mA, 100mA, 300mA

    Customization:

    Residual Current Device Type UL1053 (HAROK VKL11)
    • Brand Name: HAROK
    • Model Number: VKL11
    • Place of Origin: CHINA
    • Certification: NF, SEMKO, VDE, KEMA, ISI, CE
    • Minimum Order Quantity: 1000
    • Packaging Details: PAPER CARTON
    • Delivery Time: 4-6 weeks after payment
    • Supply Ability: 100,000 PCS PER MONTH
    • Rated Residual Operating Current: 30mA, 100mA, 300mA
    • Rated Humidity: ≤95%RH
    • Rated Operating Temperature: -25℃~+40℃
    • Rated Current: 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
    • Rated Impulse Withstand Voltage: 4kV

    Packing and Shipping:

    Packaging and Shipping of Residual Current Device

    The Residual Current Device (RCD) should be packaged and shipped in a secure manner to protect it from damage caused by external factors. The packaging material should be shock absorbent and suitable for shipping given its size and weight.

    During packaging, the RCD should be placed in a box and secured with bubble wrap or packing peanuts to minimize movement while in transit. If the RCD is to be shipped internationally, it should also be packaged in a way that meets all international customs and export regulations.

    The RCD should be shipped via a reliable carrier with a tracking system to ensure that it is delivered safely and in a timely manner. Additionally, it is important to purchase the appropriate level of insurance to cover any potential damage or loss during shipment.