Sign In | Join Free | My himfr.com
Home > Residual Current Device >

VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate

    Buy cheap VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate from wholesalers
     
    Buy cheap VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate from wholesalers
    • Buy cheap VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate from wholesalers
    • Buy cheap VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate from wholesalers

    VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VML01
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate

    VML01 Residual Current Device(RCD) Type A Type AC Type ASi with Inmetro Certificate


    1. General


    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.


    1.3 Approvals and certificates

    We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity

    10mA - precision instrument leakage protection and bathroom use.

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

    300mA/500mA - protection against indirect contacts, as well as fire hazard.

    Tripping time

    Instantaneous

    It ensures instantaneous tripping(without time-delay).

    Short time delay ASi

    (High Immunity/ Avoid nuisance tripping &blinding)

    It ensures any tripping at least 10ms.

    Selective

    It ensures total discrimination with a non selective RCD placed downstream.

    VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate


    RCD | Residual Current Device


    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VML01
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)AC, A, ASi, S
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom

    3. Outline and installation dimensions (mm)


    Product Description:

    Residual Current Device (RCD) is a device designed to protect people and buildings from electrical shock and fire caused by an overload or short circuit. With a rated operating temperature of -25℃ to +40℃, protection class of IP20, rated residual operating time of 0.1s, and rated insulation voltage of 500V, this RCD provides superior safety and performance. It is the perfect choice for anyone looking for a reliable and durable RCD for their electrical system.

    Features:

    • Product Name: Residual Current Device
    • Rated Residual Operating Current: 30mA, 100mA, 300mA
    • Rated Impulse Withstand Voltage: 4kV
    • Protection Class: IP20
    • Rated Current: 16A, 25A, 32A, 40A, 63A, 80A, 100A
    • Rated Voltage: 240/415V AC
    • Residual Current Device Type AC, A, ASi
    • Residual Current Device Certificates: Inmetro, ISI, CE, NF, UKCA, SEMKO

    Applications:

    Residual Current Device (RCD) is an essential device that provides protection from electric shock, fire, and other electrical hazards. The HAROK VML01 RCD is certified to meet the highest international standards with certifications from Inmetro, NF, SEMKO, VDE, KEMA, ISI, and CE. It has a rated impulse withstand voltage of 4kV, a rated insulation voltage of 500V, a rated residual operating current of 30mA-300mA, and a rated residual operating time of 0.1s. Produced by HAROK, the VML01 RCD offers superior quality and reliability for a wide range of applications.

    The HAROK VML01 RCD is an ideal solution for industrial, commercial, and residential applications. It is suitable for use in residential homes, office buildings, and industrial facilities where it can provide protection against electrical shock. It is also suitable for use in medical facilities, laboratories, and other sensitive environments where it can provide protection from electrical hazards. The device is capable of detecting and interrupting small leakage currents, providing protection against shock, fire, and other electrical hazards.

    The HAROK VML01 RCD is a compact and reliable device with a minimum order quantity of 1000, and a supply ability of 100,000 PCS per month. It is packaged in a paper carton and has a delivery time of 4-6 weeks after payment. With its superior quality and reliability, the HAROK VML01 RCD is the ideal solution for protecting against electric shock, fire, and other electrical hazards.

    Technical Parameters:

    ParameterValue
    Rated Impact Endurance Voltage2kV
    Rated Residual Operating Current30mA, 100mA, 300mA
    Rated Humidity≤95%RH
    Rated Residual Operating Time0.1s
    Rated Voltage230V AC
    Rated Operating Temperature-25℃~+40℃
    Rated Short-Circuit Capacity10kA
    Product NameResidual Current Device
    CertificateCE, ISI, NF, SEMKO, VDE, KEMA, Inmetro
    Residual Current Device InmetroType AC, Type A, Type ASi

    Customization:

    Residual Current Device
    Brand Name: HAROK
    Model Number: VML01

    Place of Origin: CHINA

    Certification: NF, SEMKO, VDE, KEMA, ISI, CE, Inmetro

    Minimum Order Quantity: 1000pcs

    Packaging Details: PAPER CARTON

    Delivery Time: 4-6 weeks after payment

    Supply Ability: 100,000 PCS PER MONTH

    Rated Operating Temperature: -25℃~+40℃

    Rated Impact Endurance Voltage: 2kV

    Rated Current: 16A-100A

    Rated Voltage: 240/415V AC

    Packing and Shipping:

    Packaging and Shipping for Residual Current Device

    Residual Current Devices will be packaged and shipped in accordance with the following guidelines:

    • Product will be packaged in a box with appropriate cushioning material.
    • The box will be labeled with the product name, model number, and shipping address.
    • The package will be sealed with tape to ensure it remains closed during transit.
    • The package will be shipped via a reputable carrier, with tracking and insurance.
    ```
    Quality VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)