Sign In | Join Free | My himfr.com
Home > ELCB Earth Leakage Circuit Breaker >

VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE

    Buy cheap VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE from wholesalers
     
    Buy cheap VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE from wholesalers
    • Buy cheap VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE from wholesalers
    • Buy cheap VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE from wholesalers
    • Buy cheap VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE from wholesalers

    VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE

    VKL11 Earth Leakage Circuit Breaker(ELCB) NF SEMKO VDE KEMA

    1. General

    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form


    ELCB TypeSuitable for electrical networks with
    Pulsated DC currentHarmonicsSwitching surges
    AC CLASSNoNoNo
    A CLASSYesNoNo
    S, ASi CLASSYesYesYes

    A Class ELCB may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.



    1.3 Approvals and certificates

    We certify that the ELCB has been tested for the following routine tests as per IS: 12640 (Part 1): 2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity
    10mA - precision instrument leakage protection and bathroom use.
    30mA - additional protection against direct contact.
    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
    300mA/500mA - protection against indirect contacts, as well as fire hazard.
    Tripping time
    Instantaneous
    It ensures instantaneous tripping(without time-delay).
    Short time delay Si, G, KV
    It ensures any tripping at least 10ms.
    Si: Super immunised (High immunity to unwanted tripping).
    Selective
    It ensures total discrimination with a non selective ELCB(RCCB) placed downstream.
    VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE



    ELCB | Earth Leakage Circuit Breaker

    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VKL11
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)A, AC, ASi
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom



    3. Outline and installation dimensions (mm)

    ELCB | Earth Leakage Circuit Breaker

    Product Description:

    ELCB Earth Leakage Circuit Breaker TYPE A TYPE AC TYPE ASi is an important protection device used to prevent electrical damages caused by leakage current. It features a trip time of ≤0.1s and its weight varies according to the product model. The rated voltage and frequency of this ELCB is 240V/415V and 50/60Hz respectively. It is made of PA66 materials for superior durability and long-lasting performance. This ELCB Earth Leakage Circuit Breaker is suitable for residential, commercial and industrial applications where a reliable and safe power supply is required.

    Features:

    • Product Name: ELCB Earth Leakage Circuit Breaker, including ELCB Type A Type AC and Type ASi
    • Rated Current: 6A-100A
    • Dimension: According To The Product Model
    • Insulation Voltage: ≥2KV
    • Protection Grade: IP20

    Applications:

    HAROK VKL11 ELCB Earth Leakage Circuit Breaker is a kind of electrical security products. It is suitable for all kinds of AC 50Hz/60Hz, rated voltage up to 500V, rated current 6A-100A circuit. This ELCB is a protective device that can cut off the fault circuit immediately when it detects leakage current of the circuit, so as to ensure the safety of people and property. It is certified by NF, SEMKO, VDE, KEMA, and the minimum order quantity is 1000. The packaging details are paper carton and the delivery time is 4-6 weeks after payment. FOB NINGBO or SHANGHAI is accepted for payment and the supply ability is 100,000 PCS per month. The weight and dimension of the product are decided by the product model. The insulation voltage of HAROK VKL11 ELCB is greater than 2KV, and the rated sensitivity is 30mA/100mA/300mA.

    Technical Parameters:

    SpecificationsELCB TYPE F
    Rated Voltage240V/415V
    Operating Environment Temperature-25℃~+50℃
    Rated Frequency50/60Hz
    WeightAccording To The Product Model
    Trip Time≤0.1s
    DimensionAccording To The Product Model
    MaterialPA66
    Installation MethodCable/Pin-type busbar
    Rated Sensitivity30mA/100mA/300mA

    Customization:

    We offer customized ELCB TYPE EV Earth Leakage Circuit Breaker from HAROK with model number VKL11. Our ELCB UL1053 is certified with NF, SEMKO, VDE, KEMA. The minimum order quantity is 1000, and the package is paper carton. The delivery time is 4-6 weeks after payment. The payment terms are FOB NINGBO or SHANGHAI. We have a supply ability of 100,000 PCS PER MONTH. The insulation voltage is ≥2KV, with a rated frequency of 50/60Hz. The protection grade is IP20, and the material is PA66. The rated current ranges from 6A-100A.

    Packing and Shipping:

    Packaging and Shipping Instructions for ELCB Earth Leakage Circuit Breaker

    Packaging:

    • ELCB Earth Leakage Circuit Breaker should be placed in a protective box with adequate cushioning material.
    • Label the box with "Fragile" and "This Side Up" to ensure proper handling.
    • Secure the box with packaging tape.

    Shipping:

    • Choose a reliable carrier and shipping method that offers tracking and insurance.
    • Include a completed packing list and shipping label.
    • Pack the box securely and inspect prior to shipment.

    Quality VKL11 Earth Leakage Circuit Breaker NF SEMKO VDE for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)