    VKL11 Earth Leakage Circuit Breaker ELCB UL1053

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA
    Delivery Time : 4-6 weeks after payment
    Payment Terms : FOB NINGBO or SHANGHAI
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VKL11 Earth Leakage Circuit Breaker ELCB UL1053

    VKL11 Earth Leakage Circuit Breaker(ELCB) UL1053

    1. General

    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form


    ELCB TypeSuitable for electrical networks with
    Pulsated DC currentHarmonicsSwitching surges
    AC CLASSNoNoNo
    A CLASSYesNoNo
    S, ASi CLASSYesYesYes

    A Class ELCB may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.



    1.3 Approvals and certificates

    We certify that the ELCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity
    10mA - precision instrument leakage protection and bathroom use.
    30mA - additional protection against direct contact.
    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
    300mA/500mA - protection against indirect contacts, as well as fire hazard.
    Tripping time
    Instantaneous
    It ensures instantaneous tripping(without time-delay).
    Short time delay Si, G, KV
    It ensures any tripping at least 10ms.
    Si: Super immunised (High immunity to unwanted tripping).
    Selective
    It ensures total discrimination with a non selective ELCB(RCCB) placed downstream.
    VKL11 Earth Leakage Circuit Breaker ELCB UL1053



    ELCB | Earth Leakage Circuit Breaker

    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VKL11
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)A, AC, ASi
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom



    3. Outline and installation dimensions (mm)

    ELCB | Earth Leakage Circuit Breaker

    Product Description:

    ELCB Earth Leakage Circuit Breaker is a device designed to provide reliable protection against earth leakage and short circuit current. It is made of high-grade PA66 materials and is able to withstand temperatures ranging from -25℃ to +50℃. It is also certified with NF, SEMKO, VDE, and KEMA. The insulation voltage is ≥2KV and the rated current is from 6A to 100A. ELCB Earth Leakage Circuit Breaker is highly reliable and is able to effectively protect against electrical hazards.

    Features:

    • Product Name: ELCB Earth Leakage Circuit Breaker
    • Rated Breaking Capacity: 10KA
    • Rated Sensitivity: 30mA/100mA/300mA
    • Protection Grade: IP20
    • Material: PA66
    • Rated Current: 6A-100A
    • Compliance Standard: ELCB TYPE EV, IEC/EN 61008-1 AS/NZS61008.1

    Customization:

    ELCB Earth Leakage Circuit Breaker

    Brand Name: HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Certification: NF, SEMKO, VDE, KEMA

    Minimum Order Quantity: 1000

    Packaging Details: PAPER CARTON

    Delivery Time: 4-6 weeks after payment

    Payment Terms: FOB NINGBO or SHANGHAI

    Supply Ability: 100,000 PCS PER MONTH

    Installation Method: Cable/Pin-type busbar

    Dimension: According To The Product Model

    Protection Grade: IP20

    Rated Current: 6A-100A

    Keywords: ELCB Type A Type AC Type ASi, ELCB UL1053

    Packing and Shipping:

    Packaging and Shipping for ELCB Earth Leakage Circuit Breaker

    ELCB Earth Leakage Circuit Breaker must be packaged and shipped according to the following instructions:

    1. All ELCB Earth Leakage Circuit Breaker must be placed in a heavy-duty box or crate.
    2. The box or crate must be sealed with strong tape.
    3. The box or crate must be labeled clearly with the product name and destination.
    4. The box or crate must be placed on a flat surface for transportation.
    5. The box or crate must be handled with care during transportation.
    6. The box or crate must be delivered to the destination in a timely manner.
    Quality VKL11 Earth Leakage Circuit Breaker ELCB UL1053 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)