    VAL003 Ground Fault Circuit Interrupter Breaker

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VAL003
    • Product Details
    • Company Profile

    VAL003 Ground Fault Circuit Interrupter Breaker



    VAL003 GFCI | Ground Fault Circuit Interrupter

    1. General

    VAL003 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial,

    high-rise buildings and residential houses.


    2. Technical parameters

    2.1 The tripping characteristic curves are as shown below.


    2.2 Basic parameters

    StandardIEC/EN 61009-1
    Main SpecificationsModel No.VAL003
    Rated current In5A, 6A, 10A, 13A, 15A, 16A, 20A, 25A, 30A, 32A, 35A, 40A
    Classified by Type of Instantaneous TrippingType B: (3 ~ 5) In, Type C: (5 ~ 10) In
    Poles1P + N
    Type (wave form of the earth leakage sensed)Type AC, Type A
    Mechanical featuresRated voltage UeAC240V, AC120V
    Frame size rated current In40A
    Rated residual operating current I△n6mA, 10mA, 30mA, 100mA, 300mA
    Rated residual non-operating current I△no3mA, 5mA, 15mA, 50mA, 150mA
    Rated short-circuit breaking capacity Icn240V: 4500A, 6000A, 10000A 120V: 15000A

    Rated residual making and

    breaking capacity I△m

    500A
    Electrical life2,000
    Mechanical life2,000
    Rated impulse withstand voltage Uimp4000V
    ConnectionFrom top and bottom, from bottom and top

    2.3 The residual current breaking times

    In (A)I△n (A)Breaking time when the residual current assumes the following values (s)
    I△n2I△n5I△n5A, 10A, 20A, 50A, 100A, 200A, 500A(a)I△t(b)
    6~400.01, 0.03, 0.1, 0.30.10.050.040.040.04

    a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

    B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.


    2.4 The over-current protection characteristics

    No.Rated current In (A)Initial stateTest current (A)Specified time (t)Expected resultRemarks
    a6 ~ 40Cold state1.13 Int ≥ 1hNon-tripping
    bImmediately after sequence a1.45 Int < 1hTrippingIncrease to the specified current within 5s after test item a.
    cCold state2.55 In1s < t < 60sTripping
    dCold state3 Int ≥ 0.1sNon-trippingType B
    5 Int < 0.1sTripping
    5 Int ≥ 0.1sNon-trippingType C
    10 Int < 0.1sTripping

    3. Outline and installation dimensions (mm)

    ___________________________________________________________________________________________________________________

    Product Description:

    GFCI Circuit Breaker is a type B RCBO (Residual Current Breakers with Overload) circuit breaker which provides reliable ground fault protection. It is rated for 120/240VAC and offers an indicator light to indicate when it is on or off. It is easy to install with its plug-in mounting type. With this GFCI circuit breaker, you can be assured of a safe and reliable current flow.

    Features:

    • Product Name: GFCI Circuit Breaker
    • Trip Type: Thermal Magnetic
    • CSA Certified: Yes
    • Interrupt Rating: 10kA
    • Ground Fault Protection: Yes
    • Terminal Type: Push-in
    • RCBO Circuit Breaker

    Applications:

    Introducing HAROK's GFCI Circuit Breakers

    HAROK is proud to introduce its GFCI Circuit Breaker line of products, including the VRL01, VRL02, VRL03, VRL11, VAL003, VKL003, VDL006, and VRL22 models. Providing ground fault protection, these GFCI Circuit Breakers are UL listed and mounted with a plug-in type. An indicator light allows for improved visibility and safety.

    GFCI Circuit Breakers are an ideal choice for a variety of applications, such as residential and commercial buildings. They are also ideal for use in both RCBO and RCBO Type A Circuit Breakers, providing superior protection in a wide range of industrial and commercial settings.

    HAROK GFCI Circuit Breakers provide superior performance and advanced design features to ensure increased safety and reliability. With advanced surge protection and overload protection technology, these GFCI Circuit Breakers are a must-have for both residential and commercial settings.

    For all your GFCI Circuit Breaker needs, choose HAROK. Our GFCI Circuit Breakers provide reliable protection and are backed by our industry-leading customer service and support.

    Technical Parameters:

    Wire Gauge14-2 AWG
    Voltage Rating120/240VAC
    Product NameGFCI Circuit Breaker
    Interrupt Rating10kA
    CSA CertifiedYes
    Number of Poles1 Pole
    NEMA RatingNEMA 1
    Mounting TypePlug-in
    Amperage Rating15A
    UL ListedYes
    Ground Fault Circuit Interrupter (GFCI)Yes
    RCBO Type BYes

    Customization:

    HAROK GFCI Circuit Breaker

    Brand Name: HAROK

    Model Numbers: VAL003,

    Place of Origin: CHINA

    UL Listed: Yes

    Frequency Rating: 50/60 Hz

    Number of Poles: 1 Pole

    Mounting Type: Plug-in

    Wire Gauge: 14-2 AWG

    HAROK GFCI Circuit Breaker for Ground Fault Circuit Interrupter (RCBO)

    HAROK GFCI Circuit Breaker is a reliable, UL-listed circuit breaker for ground fault circuit interrupter (RCBO) applications. Our GFCI circuit breakers feature a frequency rating of 50/60 Hz, a 1 pole mounting type, and a wire gauge of 14-2 AWG.

    Packing and Shipping:

    Packaging and Shipping for GFCI Circuit Breaker

    GFCI Circuit Breaker must be packaged and shipped in accordance with the following instructions.

    • The GFCI Circuit Breaker must be secured in a box that is large enough to accommodate the product and any accompanying accessories.
    • The box must be closed and sealed securely with packing tape.
    • The box must be clearly marked with the product name and address of the sender.
    • The box must be sent via a traceable delivery service.
    • The box must be stored in a dry and cool location prior to shipment.

    GFCI | Ground Fault Circuit Interrupter

    Quality VAL003 Ground Fault Circuit Interrupter Breaker for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)