    Brand Name : HAROK
    Model Number : VKL11
    • Product Details
    • Company Profile

    High Immunity Residual Current Circuit Breaker Type B

    High immunity Residual Current Circuit Breaker Type B


    1. General


    1.1 Function

    VKL11B RCCB and VKL11B+ RCCB is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

    Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

    Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

    They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.


    1.2 Selection


    Detectable wave form


    Type B

    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.


    Type B+

    Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA


    Tripping sensitivity

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;

    300mA - protection against indirect contacts, as well as fire hazard.


    Tripping time

    Instantaneous It ensures instantaneous tripping(without time-delay).

    Short time delay

    Selective (time delay)


    1.3 Approvals and certificates


    RCCB | Residual Current Circuit Breaker


    2. Technical parameters


    TypeBB+
    Electrical
    Design according toIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    VDE 0664-400
    Current test marks as printed onto the device
    Rated voltage Un

    2P: 230/240V AC

    4P: 400/415V AC

    Rated frequency fn50/60Hz
    Mode of operation

    "A type functionality: voltage independent

    B and B+ type functionality: voltage dependent"

    Operation voltage electronic50 – 264V AC
    Voltage range test circuit

    2P: 184 – 264V AC

    4P: 184 – 440V AC

    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A

    Rated residual

    operating

    current I△n

    Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    S- selective100mA, 300mA, 500mA100mA, 300mA
    SensitivityAlternating, pulsed and smooth direct currents
    High frequency up to 1 kHZHigh frequency up to 20kHZ
    Rated insulation voltage Ui500 V
    Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
    Rated conditional short-circuit current Inc10 kA
    Rated making and breaking capacity Im1500 A
    Peak withstand current

    3 kA (8/20 μs) surge current proof

    5 kA (8/20 μs) surge current proof for type S

    Electrical isolation> 4 mm contact space

    Maximum back-up fuse

    In = 16-100A

    Short circuit and overload protection

    100 A gG/gL

    Endurance

    (operating cycles)

    electrical components≥ 2000
    mechanical components≥ 4000
    Mechanical
    Degree of protectionIP20
    Upper and lower terminalsopen mounted / lift terminals
    Terminal capacity1 - 25 mm2
    Terminal torque2 - 2.5 Nm
    Busbar thickness0.8 - 2 mm
    Operating temperature-25°C ... +55°C
    Storage- and transport temperature-40°C ... +70°C
    Resistance to climatic conditionsIEC/EN 61008
    Contact position indicatormechanical red / green
    Supply possibilitytop or bottom
    Mounting positionany

    3. Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)


    3.1 Applications

    Typical applications that are vulnerable to smooth DC residual currents:

    - Frequency converters with a three-phase connection

    - Medical equipment such as X-ray equipment or CT machines

    - Photovoltaic or UPS systems

    - Connection points (wall boxes, charging stations) for electric vehicles

    - Elevator controllers

    - Pipeline trace heating

    - Test setups in laboratories

    - Construction sites in accordance with BGI 608 information leaflet (Electronic equipment on construction sites)

    - Charging stations for battery-powered forklift trucks

    - Cranes of all kinds

    - Mixing plants if relevant loads are connected

    - Variable-speed machine tools, such as milling and grinding machines or lathes


    4. Wiring diagrams



    5. Tripping characteristics


    B type


    6. Dimensions (mm)


    Product Description:

    RCCB TYPE B is a high-performance residual current circuit breaker, designed with rated making and breaking capacity Im of 1500A, electrical endurance of ≥ 2000, degree of protection of IP20, rated residual operating current I△n of 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA) and rated frequency of 50/60Hz. It provides excellent protection against electric shock and fire caused by earth leakage current and features high immunity. It is ideal for use in residential, commercial and industrial applications.

    Features:

    • Product Name: High immunity RCCB TYPE B
    • Sensitivity: Alternating, Pulsed and Smooth Direct Currents (High Frequency up to 1 KHZ)
    • Mechanical Endurance: ≥ 4000
    • Rated insulation voltage Ui: 500V
    • Electrical Endurance: ≥ 2000
    • Busbar thickness: 0.8 - 2 Mm

    Applications:

    Harok VKL11 Super Immunised RCCB TYPE B

    Harok's VKL11 Super Immunised RCCB TYPE B is a highly-reliable voltage dependent circuit breaker designed for use in various indoor applications. With a rated insulation voltage of 500V, it provides superior protection with a degree of protection IP20 and electrical endurance of ≥ 2000. The circuit breaker is manufactured with a rated frequency of 50/60Hz. It is also designed with a voltage dependent mode of operation, making it a safe and durable choice for a variety of applications.

    Harok's VKL11 Super Immunised RCCB TYPE B is suitable for use in various indoor environments ranging from residential and commercial premises to industrial facilities. It is compliant with the IEC 61009-1 standard for residual current circuit breakers and is ideal for use in applications where safety and reliability are of paramount importance. Furthermore, it is an excellent choice for areas where frequent switching is required, as it ensures accurate and reliable protection from overcurrent and short circuit.

    Harok's VKL11 Super Immunised RCCB TYPE B is a cost-effective solution for a variety of applications. With its superior protection, electrical endurance and reliable operation, it is an excellent choice for a wide range of indoor applications.

    Technical Parameters:

    Product NameRCCB TYPE B
    Rated Frequency50/60Hz
    Rated impulse withstand voltage Uimp4 KV (1.2/50μs)
    Mechanical Endurance≥ 4000
    Rated making and breaking capacity Im1500A
    Degree of protectionIP20
    Rated voltage Un2P 230/240V~; 4P 400/415V~
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    SensitivityAlternating, Pulsed And Smooth Direct Currents (High Frequency Up To 1 KHZ)
    StandardIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    Special FeatureSuper immunised RCCB, High immunity RCCB

    Customization:

    HAROK VKL11 High Immunity RCCB TYPE B

    Brand Name: HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Electrical Endurance: ≥ 2000

    Rated current In: 16A, 25A, 32A, 40A, 63A, 80A, 100A

    Degree of protection: IP20

    Rated voltage Un: 2P 230/240V~; 4P 400/415V~

    Rated residual operating current I△n: 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA)

    Super immunised RCCB, High immunity RCCB.

    Packing and Shipping:

    Packaging and Shipping for RCCB TYPE B:

    • The product is packed in a cardboard box with a protective foam layer;
    • The box is sealed with plastic tape;
    • The box is labeled with product and company information;
    • The product is shipped via air freight or ground freight, depending on customer preference.
    Quality High Immunity Residual Current Circuit Breaker Type B for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)