    Super immunity RCCB TYPE B


    1. General


    1.1 Function

    VKL11B RCCB and VKL11B+ RCCB is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

    Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

    Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

    They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.


    1.2 Selection


    Detectable wave form


    Type B

    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.


    Type B+

    Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA


    Tripping sensitivity

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;

    300mA - protection against indirect contacts, as well as fire hazard.


    Tripping time

    Instantaneous It ensures instantaneous tripping(without time-delay).

    Short time delay

    Selective (time delay)


    1.3 Approvals and certificates


    RCCB | Residual Current Circuit Breaker


    2. Technical parameters


    TypeBB+
    Electrical
    Design according toIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    VDE 0664-400
    Current test marks as printed onto the device
    Rated voltage Un

    2P: 230/240V AC

    4P: 400/415V AC

    Rated frequency fn50/60Hz
    Mode of operation

    "A type functionality: voltage independent

    B and B+ type functionality: voltage dependent"

    Operation voltage electronic50 – 264V AC
    Voltage range test circuit

    2P: 184 – 264V AC

    4P: 184 – 440V AC

    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A

    Rated residual

    operating

    current I△n

    Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    S- selective100mA, 300mA, 500mA100mA, 300mA
    SensitivityAlternating, pulsed and smooth direct currents
    High frequency up to 1 kHZHigh frequency up to 20kHZ
    Rated insulation voltage Ui500 V
    Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
    Rated conditional short-circuit current Inc10 kA
    Rated making and breaking capacity Im1500 A
    Peak withstand current

    3 kA (8/20 μs) surge current proof

    5 kA (8/20 μs) surge current proof for type S

    Electrical isolation> 4 mm contact space

    Maximum back-up fuse

    In = 16-100A

    Short circuit and overload protection

    100 A gG/gL

    Endurance

    (operating cycles)

    electrical components≥ 2000
    mechanical components≥ 4000
    Mechanical
    Degree of protectionIP20
    Upper and lower terminalsopen mounted / lift terminals
    Terminal capacity1 - 25 mm2
    Terminal torque2 - 2.5 Nm
    Busbar thickness0.8 - 2 mm
    Operating temperature-25°C ... +55°C
    Storage- and transport temperature-40°C ... +70°C
    Resistance to climatic conditionsIEC/EN 61008
    Contact position indicatormechanical red / green
    Supply possibilitytop or bottom
    Mounting positionany

    3. Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)


    3.1 Applications

    Typical applications that are vulnerable to smooth DC residual currents:

    - Frequency converters with a three-phase connection

    - Medical equipment such as X-ray equipment or CT machines

    - Photovoltaic or UPS systems

    - Connection points (wall boxes, charging stations) for electric vehicles

    - Elevator controllers

    - Pipeline trace heating

    - Test setups in laboratories

    - Construction sites in accordance with BGI 608 information leaflet (Electronic equipment on construction sites)

    - Charging stations for battery-powered forklift trucks

    - Cranes of all kinds

    - Mixing plants if relevant loads are connected

    - Variable-speed machine tools, such as milling and grinding machines or lathes


    4. Wiring diagrams



    5. Tripping characteristics


    B type


    6. Dimensions (mm)


    Product Description:

    The Super immunised RCCB (Residual Current Circuit Breaker) Type B is a high-immunity device designed to detect and protect people and equipment from electric shock and fire caused by indirect contact, leakage and earth fault current. This product is designed to meet international safety standards including IEC/EN 62423, IEC/EN 61008-1, and OVE E8601. It has a rated frequency of 50/60Hz and a rated voltage of 2P 230/240V~; 4P 400/415V~. The rated current of this Type B RCCB is from 16A to 100A with a degree of protection of IP20.

    Features:

    • Product Name: RCCB TYPE B
    • Rated voltage Un: 2P 230/240V~; 4P 400/415V~
    • Rated making and breaking capacity Im: 1500A
    • Mode of operation: Voltage Dependent
    • Standard: IEC/EN 62423, IEC/EN 61008-1, OVE E8601
    • Busbar thickness: 0.8 - 2 Mm
    • Residual Current Circuit Breaker (RCCB) for reliable protection against indirect contact

    Applications:

    HAROK's VKL11 High immunity RCCB is a reliable device of degree of protection IP20, with rated current In of 16A, 25A, 32A, 40A, 63A, 80A, 100A and rated frequency of 50/60Hz. It is manufactured in CHINA, and certified to IEC/EN 62423, IEC/EN 61008-1, OVE E8601. It has a rated impulse withstand voltage of 4 KV (1.2/50μs). The product is designed to be used in diverse applications with high immunity demands, such as commercial, industrial, and residential electrical installations.

    Technical Parameters:

    ParameterValue
    Electrical Endurance≥ 2000
    Rated making and breaking capacity Im1500A
    Mode of operationVoltage Dependent
    SensitivityAlternating, Pulsed And Smooth Direct Currents (High Frequency Up To 1 KHZ)
    Rated residual operating current I△n30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA)
    Rated Frequency50/60Hz
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated voltage Un2P 230/240V~; 4P 400/415V~
    Busbar thickness0.8 - 2 Mm
    Product NameRCCB TYPE B
    KeywordsResidual Current Circuit Breaker, Super immunised RCCB

    Customization:

    RESIDUAL CURRENT CIRCUIT BREAKER (RCCB) TYPE B

    Brand Name: HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Rated Making and Breaking Capacity Im: 1500A

    Degree of Protection: IP20

    Standard: IEC/EN 62423, IEC/EN 61008-1, OVE E8601

    Mode of Operation: Voltage Dependent

    Busbar Thickness: 0.8 - 2 Mm

    Our RCCB TYPE B is a super immunised Residual Current Circuit Breaker that provides protection against electric shock and fire caused by indirect contacts. It is designed and manufactured with Brand Name HAROK, Model Number VKL11. It has a rated making and breaking capacity of 1500A and IP20 Degree of Protection. This RCCB meets the standards of IEC/EN 62423, IEC/EN 61008-1, OVE E8601 and works in a Voltage Dependent mode. The Busbar Thickness is 0.8 - 2 Mm.

    Packing and Shipping:

    The Packaging and Shipping of RCCB TYPE B is as follows:

    • The product is packaged in a durable, well-designed cardboard box.
    • The product is placed in a foam padded container to ensure that it is kept safe during shipping.
    • The product is shipped using a reputable delivery service, such as FedEx, UPS or DHL.
    • The product is insured during shipping and is delivered to the customer with a tracking number.
    Quality Super Immunity RCCB TYPE B for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)