    1. General


    1.1 Function

    VKL11B RCCB and VKL11B+ RCCB is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

    Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

    Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

    They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.


    1.2 Selection


    Detectable wave form


    Type B

    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.


    Type B+

    Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA


    Tripping sensitivity

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;

    300mA - protection against indirect contacts, as well as fire hazard.


    Tripping time

    Instantaneous It ensures instantaneous tripping(without time-delay).

    Short time delay

    Selective (time delay)


    1.3 Approvals and certificates


    RCCB | Residual Current Circuit Breaker


    2. Technical parameters


    TypeBB+
    Electrical
    Design according toIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    VDE 0664-400
    Current test marks as printed onto the device
    Rated voltage Un

    2P: 230/240V AC

    4P: 400/415V AC

    Rated frequency fn50/60Hz
    Mode of operation

    "A type functionality: voltage independent

    B and B+ type functionality: voltage dependent"

    Operation voltage electronic50 – 264V AC
    Voltage range test circuit

    2P: 184 – 264V AC

    4P: 184 – 440V AC

    Rated current In25A

    Rated residual

    operating

    current I△n

    Instantaneous30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    K-short time delayed (G, ASi)30mA, 100mA, 300mA, 500mA30mA, 100mA, 300mA
    S- selective100mA, 300mA, 500mA100mA, 300mA
    SensitivityAlternating, pulsed and smooth direct currents
    High frequency up to 1 kHZHigh frequency up to 20kHZ
    Rated insulation voltage Ui500 V
    Rated impulse withstand voltage Uimp4 kV (1.2/50μs)
    Rated conditional short-circuit current Inc10 kA
    Rated making and breaking capacity Im1500 A
    Peak withstand current

    3 kA (8/20 μs) surge current proof

    5 kA (8/20 μs) surge current proof for type S

    Electrical isolation> 4 mm contact space

    Maximum back-up fuse

    In = 16-100A

    Short circuit and overload protection

    100 A gG/gL

    Endurance

    (operating cycles)

    electrical components≥ 2000
    mechanical components≥ 4000
    Mechanical
    Degree of protectionIP20
    Upper and lower terminalsopen mounted / lift terminals
    Terminal capacity1 - 25 mm2
    Terminal torque2 - 2.5 Nm
    Busbar thickness0.8 - 2 mm
    Operating temperature-25°C ... +55°C
    Storage- and transport temperature-40°C ... +70°C
    Resistance to climatic conditionsIEC/EN 61008
    Contact position indicatormechanical red / green
    Supply possibilitytop or bottom
    Mounting positionany

    3. Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)


    3.1 Applications

    Typical applications that are vulnerable to smooth DC residual currents:

    - Frequency converters with a three-phase connection

    - Medical equipment such as X-ray equipment or CT machines

    - Photovoltaic or UPS systems

    - Connection points (wall boxes, charging stations) for electric vehicles

    - Elevator controllers

    - Pipeline trace heating

    - Test setups in laboratories

    - Construction sites in accordance with BGI 608 information leaflet (Electronic equipment on construction sites)

    - Charging stations for battery-powered forklift trucks

    - Cranes of all kinds

    - Mixing plants if relevant loads are connected

    - Variable-speed machine tools, such as milling and grinding machines or lathes


    4. Wiring diagrams



    5. Tripping characteristics


    B type


    6. Dimensions (mm)


    Product Description:

    High immunity RCCB, Residual Current Circuit Breaker (RCCB), Residual Current Circuit Breaker Type B is a kind of over-current protective device with high immunity. It is designed to protect people and equipments against electric shock and fire caused by earth leakage. It is suitable for 2P 230/240V~ and 4P 400/415V~ AC electricity supply systems. It meets the requirements of IEC/EN 62423, IEC/EN 61008-1 and OVE E8601. Its sensitivity can detect alternating, pulsed and smooth direct currents (high frequency up to 1 KHZ). It has voltage dependent mode of operation and mechanical endurance of more than 4000. It is a reliable choice for the safety of people and equipments.

    Features:

    • Product Name: RCCB TYPE B
    • Mode of operation: Voltage Dependent
    • Busbar thickness: 0.8 - 2 Mm
    • Rated impulse withstand voltage Uimp: 4 KV (1.2/50μs)
    • Standard: IEC/EN 62423, IEC/EN 61008-1, OVE E8601
    • Degree of protection: IP20

    Applications:

    HAROK VKL11 RESIDUAL CURRENT CIRCUIT BREAKER TYPE B is a perfect solution for protecting people from electric shock or fire caused by earth leakage current. This product is highly efficient, reliable and eco-friendly, with a premium quality and a high degree of protection of IP20. It is designed to work with voltage dependent mode, offering a range of rated current In of 16A, 25A, 32A, 40A, 63A, 80A, 100A. Moreover, it has a long electrical endurance of ≥ 2000 and rated residual operating current I△n of 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)) and 100mA, 300mA, 500mA (100mA, 300mA, 500mA). With its super immunised RCCB feature, this product is ideal for use in residential, commercial and industrial applications, providing an effective and safe protection and a peace of mind.

    Technical Parameters:

    ParameterValue
    Degree of protectionIP20
    Rated residual operating current I△n30mA, 100mA, 300mA
    Rated voltage Un2P 230/240V~; 4P 400/415V~
    StandardIEC/EN 62423, IEC/EN 61008-1, OVE E8601
    Rated insulation voltage Ui500V
    Busbar thickness0.8 - 2 Mm
    Product NameRESIDUAL CURRENT CIRCUIT BREAKER TYPE B
    Rated Frequency50/60Hz
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A

    Customization:

    Customized Super immunised RCCB - RESIDUAL CURRENT CIRCUIT BREAKER, RCCB TYPE B - HAROK VKL11
    Product Details:
    • Brand Name: HAROK
    • Model Number: VKL11
    • Place of Origin: CHINA
    • Product Name: RESIDUAL CURRENT CIRCUIT BREAKER TYPE B
    • Mechanical Endurance: ≥ 4000
    • Electrical Endurance: ≥ 2000
    • Rated Frequency: 50/60Hz
    • Rated voltage Un: 2P 230/240V~; 4P 400/415V~

    Packing and Shipping:

    Packaging and Shipping for RCCB TYPE B:

    The RCCB TYPE B product is packaged in a durable cardboard box and shipped with foam insert to protect the product from any damage.

    It is then shipped to the destination via a reliable and trustworthy courier service to make sure the product is delivered in good condition.

    Quality VKL11 Residual Current Circuit Breaker Type B VDE KEMA NF for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)