Sign In | Join Free | My himfr.com
Home > Residual Current Device >

VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD

    Buy cheap VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD from wholesalers
     
    Buy cheap VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD from wholesalers
    • Buy cheap VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD from wholesalers
    • Buy cheap VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD from wholesalers
    • Buy cheap VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD from wholesalers

    VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD

    Ask Lasest Price
    Brand Name : HAROK
    Model Number : VKL11
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD

    VKL11 Residual Current Device (RCD) Type A Type AC Type ASi


    1. General

    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form

    RCD TypeSuitable for electrical networks with
    Pulsated DC currentHarmonicsSwitching surges
    AC CLASSNoNoNo
    A CLASSYesNoNo
    S, ASi CLASSYesYesYes

    A Class RCD may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.



    1.3 Approvals and certificates

    We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity
    10mA - precision instrument leakage protection and bathroom use.
    30mA - additional protection against direct contact.
    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
    300mA/500mA - protection against indirect contacts, as well as fire hazard.
    Tripping time
    Instantaneous
    It ensures instantaneous tripping(without time-delay).
    Short time delay ASi
    (High Immunity/ Avoid nuisance tripping &blinding)
    It ensures any tripping at least 10ms.
    Selective
    It ensures total discrimination with a non selective RCD placed downstream.
    VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD



    RCD | Residual Current Device

    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VKL11
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)AC, A, ASi, S
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom



    3. Outline and installation dimensions (mm)

    Product Description:

    Residual Current Device (RCD) Inmetro, Type EV, manufactured by ABB, is an electrical safety device that provides protection against electric shock. It monitors the current in the circuit and trips when it detects an imbalance between the lines, thus protecting people from electric shock. The RCD has a rated residual operating time of 0.1s, a rated residual non-operating current of 0.5mA, and a rated impact endurance voltage of 2kV. It is certified by CE, ISI, NF, SEMKO, VDE, and KEMA, and is designed to operate at a rated frequency of 50/60Hz. The RCD is a reliable and efficient safety device that offers optimal protection for both operators and consumers.

    Features:

    • Product Name: Residual Current Device
    • Rated Short-Circuit Capacity: 10kA
    • Rated Frequency: 50/60Hz
    • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA
    • Rated Operating Temperature: -25℃~+40℃
    • Residual Current Device Type: TYPE AC, TYPE A, TYPE ASi
    • Certificate: Inmetro, NF, ISI, SEMKO, UKCA, CE, VDE

    Applications:

    HAROK VKL11 is a Residual Current Device (RCD) that offers a reliable and efficient protection from electric shock due to its advanced construction and features. The device is certified by NF, SEMKO, VDE, KEMA, ISI and CE, which guarantees its quality and safety. It has a rated residual operating time of 0.1s, rated operating temperature of -25℃~+40℃, rated current of 16A-100A. It also has a rated impulse withstand voltage of 4kV. The minimum order quantity is 1000 and the packaging details are paper carton. Delivery time is 4-6 weeks after payment and the supply ability is 100,000 PCS per month. The RCD type AC, Type A and Type ASi are available in this product.

    Technical Parameters:

    Product NameResidual Current Device
    CertificateCE, ISI, NF, SEMKO, VDE, KEMA, Inmetro
    TypeType AC, Type A, Type ASi
    Rated Voltage240/415V AC
    Rated Frequency50/60Hz
    Rated Current16A-100A
    Rated Residual Operating Current30mA, 100mA, 300mA
    Rated Operating Temperature-25℃~+40℃
    Protection ClassIP20

    Customization:

    Residual Current Device by HAROK

    Model Number: VKL11

    Place of Origin: CHINA

    Certification: NF, SEMKO, VDE, KEMA, ISI, CE, Inmetro

    Minimum Order Quantity: 1000pcs

    Packaging Details: PAPER CARTON

    Delivery Time: 4-6 weeks after payment

    Supply Ability: 100,000 PCS PER MONTH

    Rated Operating Temperature: -25℃~+40℃

    Rated Current: 16A-100A

    Rated Frequency: 50/60Hz

    Rated Humidity: ≤95%RH

    Rated Impulse Withstand Voltage: 4kV

    Residual Current Device Type AC, Type A, Type ASi

    HAROK Residual Current Device VKL11, with Type AC, Type A, Type ASi, is Inmetro certified product. This RCD is highly reliable with rated operating temperature range of -25℃~+40℃, rated residual current of 30mA to 300mA, rated frequency of 50/60Hz and rated humidity of ≤95%RH. It is also tested for withstanding voltage up to 4kV. The minimum order quantity of this product is 1000. Delivery takes 4-6 weeks after payment and we are able to supply up to 100,000 PCS PER MONTH. Packaging details are PAPER CARTON.

    Packing and Shipping:

    Packaging and Shipping for Residual Current Device:

    • The product must be packaged in a strong cardboard box.
    • The box should be securely sealed with strong adhesive tape.
    • The product should be cushioned with foam or bubble wrap.
    • The box should be clearly labeled with the product details and address of the recipient.
    • The package should be shipped via a reliable shipping service, such as FedEx, UPS, or DHL.
    Quality VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)