    Brand Name : HAROK
    Model Number : VML01
    Certification : NF, SEMKO, VDE, KEMA, ISI, CE
    Delivery Time : 4-6 weeks after payment
    Supply Ability : 100,000 PCS PER MONTH
    • Product Details
    • Company Profile

    VML01 Residual Current Device RCD Inmetro Certified- Rated Rated Frequency 50/60Hz

    VML01 Residual Current Device(RCD) Inmetro


    1. General


    1.1 Function

    Control electric circuits.

    Protect people against indirect contacts and additional protection against direct contacts.

    Protect installations against fire hazard due to insulation faults.

    Residual current circuit breakers are used in housing, tertiary sector and industry.


    1.2 Selection

    Detectable wave form

    AC class

    Tripping is ensured for slowly increasing sinusoidal AC residual currents


    A class

    Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


    ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

    Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

    Note: Our ASi type includes G/KV function and Si function.


    1.3 Approvals and certificates

    We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

    with the requirements.

    1. Verification of the operating characteristic as per Seq. - D0 CL9.9

    2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

    3. High Voltage Test as per D.3 of Annex D

    4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

    Tripping sensitivity

    10mA - precision instrument leakage protection and bathroom use.

    30mA - additional protection against direct contact.

    100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

    300mA/500mA - protection against indirect contacts, as well as fire hazard.

    Tripping time

    Instantaneous

    It ensures instantaneous tripping(without time-delay).

    Short time delay ASi

    (High Immunity/ Avoid nuisance tripping &blinding)

    It ensures any tripping at least 10ms.

    Selective

    It ensures total discrimination with a non selective RCD placed downstream.

    VML01 Residual Current Device RCD Inmetro Certified- Rated Rated Frequency 50/60Hz


    RCD | Residual Current Device


    2. Technical parameters

    StandardIEC/EN 61008-1 AS/NZS61008.1
    Electrical featuresModel No.VML01
    Poles2P, 4P
    Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
    Rated voltage Ue2P: 240V 4P: 415V
    Insulation voltage Ui415V
    Rated frequency50/60 Hz
    Rated residual making and breaking capacity I△m1500A
    Short-circuit current Inc=I△c6000A, 10000A
    Type (wave form of the earth leakage sensed)AC, A, ASi, S
    break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
    Rated impulse withstand voltage(1.2/50) Uimp4kV
    Dielectric test voltage at ind. Freq. for 1 min2.5
    Pollution degree2
    Mechanical featuresElectrical life≥2000
    Mechanical life≥2000
    Fault current indicatorYes
    Terminal protection degreeIP20

    Ambient temperature (with

    daily average≤35℃)

    -25℃ to 50℃
    Storage temperate-30℃ to 70℃
    InstallationTerminal connection typeCable/Pin-type busbar
    Terminal size top/bottom for cable25-35 mm²
    18-3/18-2 AWG
    Terminal size top/bottom for busbar10/16 mm²
    18-8/18-5 AWG
    Tightening torque2.5 N·m
    22 In-Ibs.
    MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
    ConnectionFrom top and bottom

    3. Outline and installation dimensions (mm)


    Product Description:

    A Residual Current Device (RCD) is a safety device that protects people from electric shocks and prevents fires. It is an essential part of any electrical installation. RCDs are designed to detect any imbalance in the electrical circuit and interrupt the current flow when it occurs. This device is designed for use in AC circuits and is certified according to Inmetro standards. It is available in three types: Type AC, Type A and Type ASi.

    The RCD Type AC is rated for a short-circuit capacity of 10kA, a rated current of 30mA, a rated frequency of 50/60Hz and a rated impulse withstand voltage of 4kV. It also has a protection class of IP20. This device helps to protect people and property from electricity-related hazards, making it an invaluable addition to any electrical installation.

    Features:

    • Product Name: Residual Current Device
    • Rated Residual Operating Time: 0.1s
    • Rated Insulation Voltage: 500V
    • Rated Humidity: ≤95%RH
    • Rated Short-Circuit Capacity: 10kA
    • Rated Impact Endurance Voltage: 2kV
    • Residual Current Device Type: A, AC, ASi
    • Residual Current Device Inmetro: Certified

    Applications:

    HAROK's VKL11 Residual Current Device Type A, AC, ASi is the perfect choice for providing reliable and dependable protection against electric shock. It is certified by Inmetro, NF, SEMKO, VDE, KEMA, ISI, and CE and has a minimum order quantity of 1000. The rated insulation voltage is 500V, the rated humidity is ≤95%RH, the rated impact endurance voltage is 2kV, the rated current is 16, 20A, 25A, 32A, 40A, 63A, 80A, 100A, and the rated residual operating time is 0.1s. The device is packaged in a paper carton and is available for delivery within 4-6 weeks after payment. The maximum monthly supply is 100,000 PCS.

    The VKL11 RCD has advanced safety features and is suitable for a wide range of industrial, commercial, and residential applications. It is also ideal for use in areas where there is a risk of electric shock, such as bathrooms, kitchens, and other wet locations. The device is designed to detect leakage currents and instantly disconnect the power supply to protect users from electric shock. It also helps to reduce the risk of fires and other damage caused by electrical faults.

    The VKL11 RCD is a great choice for providing reliable and long-lasting protection against electric shock. It is easy to install and use and requires minimal maintenance. Its advanced safety features make it an ideal choice for a variety of applications. The device is reliable and dependable and will provide years of worry-free protection.

    Technical Parameters:

    ParameterValue
    Residual Current Device TypeType AC, Type A, Type ASi
    Rated Residual Operating Current30mA, 100mA, 300mA

    Ambient temperature

    (with daily average≤35℃)

    -25℃ to 55℃

    Storage temperature

    -40℃ to 70℃

    Rated Frequency50/60Hz
    Rated Current16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
    Rated Impact Endurance Voltage2kV
    Rated Insulation Voltage500V
    Rated Residual Operating Time0.1s
    Rated Voltage240/415V AC
    Rated Short-Circuit Capacity10kA

    Customization:

    Residual Current Device (RCD)
    • Brand Name: HAROK
    • Model Number: VKL11
    • Place of Origin: CHINA
    • Certification: NF, SEMKO, VDE, KEMA, ISI, CE
    • Minimum Order Quantity: 1000
    • Packaging Details: PAPER CARTON
    • Delivery Time: 4-6 weeks after payment
    • Supply Ability: 100,000 PCS PER MONTH
    • Protection Class: IP20
    • Rated Impulse Withstand Voltage: 4kV
    • Rated Operating Temperature: -25℃~+40℃
    • Rated Current: 16A-100A
    • Residual Current Device Type: Type AC, Type A, Type ASi

    Packing and Shipping:

    Packaging and Shipping of Residual Current Device

    In order to ensure the safety of the Residual Current Device (RCD) during the shipping process, the following guidelines must be followed:

    • Always ensure that the packaging is kept dry and free from dust and dirt.
    • Always make sure that the RCD is adequately protected from impacts and shocks.
    • Always make sure that the package is clearly labeled with the appropriate shipping information.
    • Always ensure that the RCD is correctly secured in the package.
    • Always use appropriate shipping materials for the package, such as bubble wrap and packing peanuts.
    • Always make sure that the package is properly sealed and that the package is labeled as "fragile" or "handle with care".
    Quality VML01 Residual Current Device RCD Inmetro Certified- Rated Rated Frequency 50/60Hz for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yueqing Vorax Electric CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)